Active electronic personal dosemeter in interventional radiology.
نویسندگان
چکیده
A recently developed active electronic personal dosemeter (AEPD) was utilised in order to measure the levels and the structure of occupational exposure to scattered X-ray radiation of medical staff who performed percutaneous revascularisation therapy that involves interventional radiology (IR) on the pelvis and upper leg arteries. The AEPDs, placed on the operators' and assistants' chests, that is, above the protective apron, continuously measured and recorded the received doses and, as a novelty, dose rates as a function of time, thus yielding a unique record of occupational doses and dose rates pattern at the working place. This paper presents and discusses one typical daily pattern in which seven percutaneous interventions were performed.
منابع مشابه
Design of Active-Type Personal Dosemeter for High-Energy Neutrons
In order to design an active-type personal dosemeter having sufficient sensitivity to high-energy neutrons up to 100 MeV, the characteristic response of several types of silicon (Si) semiconductor detectors has been investigated experimentally and theoretically. At first, the response of each detector has been checked to protons accelerated by a Van de Graff accelerator installed at Kobe Univer...
متن کاملInfluence of dosemeter position for the assessment of eye lens dose during interventional cardiology.
The equivalent dose limit for the eye lens for occupational exposure recommended by the ICRP has been reduced to 20 mSv y(-1) averaged over defined periods of 5 y, with no single year exceeding 50 mSv. The compliance with this new requirement could not be easy in some workplace such as interventional radiology and cardiology. The aim of this study is to evaluate different possible approaches in...
متن کاملPerformance Test of the Electronic Personal Neutron Dosemeter in Neutron Fields Simulating Workplaces of MOX Fuel Fabrication Facilities
Recently, several electronic personal dosemeters (EPDs) capable of measuring neutron dose equivalents were developed and have appeared on the market. The authors initiated the present study to assess performance of neutron EPDs. The EPD selected for this study was NRY21, manufactured by Fuji Electric Systems Co., Ltd. This dosemeter uses two silicon semiconductor detectors (a fast neutron senso...
متن کاملEye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.
A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the fol...
متن کاملConversion from dosemeter readings to effective dose in individual dosimetric monitoring: effect of anisotropy of photon fields and dosemeter design
Monte Carlo simulation (MCNP-4B code, ADAM phantom) was employed in order to estimate organ doses and doses to personal dosemeters of particular commercial design (one type of Harshaw dosemeter and two designs of RADOS dosemeters) in situations of irradiation of a person in photon radiation fields. For each photon energy and beam direction the partial conversion coefficients were calculated pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 132 3 شماره
صفحات -
تاریخ انتشار 2008