Mid-Term Review of ADEPT Metal-On-Metal Hip Prosthesis. Functional, Radiological and Metal Ion Analysis

نویسندگان

  • James G. A. Plant
  • Gareth H. Prosser
  • Ben J. Burston
  • Stephen J. Edmondston
  • Piers J. Yates
چکیده

Background: There is much interest regarding metal-on-metal implants in medical and general media. Much of this has been regarding failure of specific implant systems and metal ion toxicity. We present our early mid-term experience of the ADEPT metal-on-metal system which has both modular and non-modular hip options. Methods: Functional assessment, blood metal ion quantification, and radiographic analysis were performed for the modular and non-modular ADEPT variants. Fifty implants were implanted with a mean follow up time of 28 months. Unpaired t-tests were used to compare modular and resurfacing groups, standardised hip scores were used to compare function to conventional total hip arthroplasty. Results: Metal ion levels were significantly higher in modular prostheses compared to resurfacing implants, but not at “harmful” levels (as determined by a previous metal-on-metal implant recall). Functional outcomes were excellent and revision rates were lower than expected. Conclusions: At our institution we have good outcomes with the ADEPT hip prosthesis. Though patient selection and implant position are crucial, poor performance of metal-on-metal hip replacements is implant specific.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ion Release from Metal-on-metal Hip Resurfacing Implants Does Not Differ from Standard Metal-on-metal Total Hip Replacement

STANDARD METAL-ON-METAL TOTAL HIP REPLACEMENT *Moroni A, **Savarino L, *Cadossi M, **Greco M, **Baldini N, *Giannini S * Rizzoli Orthopaedic Institute, Bologna, Italy **Laboratory for Pathophysiology of Orthopaedic Implants, Rizzoli Orthopaedic Institute, Bologna, Italy [email protected] INTRODUCTION Modern metal-on-metal (MOM) hip resurfacing has been introduced as a less invasive method of join...

متن کامل

Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.

BACKGROUND Metal ion toxicity, metal hypersensitivity, and metal carcinogenicity are causes for concern for patients with metal-on-metal hip replacements. Thus, understanding the biological fate of metal ions, and consequently their long-term systemic effects, is of great interest to patients and surgeons alike. METHODS Inductively coupled plasma mass spectrometry was used to measure the leve...

متن کامل

High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis.

This study reports the mid-term results of a large-bearing hybrid metal-on-metal total hip replacement in 199 hips (185 patients) with a mean follow-up of 62 months (32 to 83). Two patients died of unrelated causes and 13 were lost to follow-up. In all, 17 hips (8.5%) have undergone revision, and a further 14 are awaiting surgery. All revisions were symptomatic. Of the revision cases, 14 hips s...

متن کامل

Explant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint

OBJECTIVES The high revision rates of the DePuy Articular Surface Replacement (ASR) and the DePuy ASR XL (the total hip arthroplasty (THA) version) have led to questions over the viability of metal-on-metal (MoM) hip joints. Some designs of MoM hip joint do, however, have reasonable mid-term performance when implanted in appropriate patients. Investigations into the reasons for implant failure ...

متن کامل

Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems

BACKGROUND The purpose of the study was twofold: first, to determine whether there is a statistically significant difference in the metal ion levels among three different large-head metal-on-metal (MOM) total hip systems. The second objective was to assess whether position of the implanted prostheses, patient demographics or factors such as activity levels influence overall blood metal ion leve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014