Neuromuscular factors contributing to in vivo eccentric moment generation.
نویسندگان
چکیده
Muscle series elasticity and its contribution to eccentric moment generation was examined in humans. While subjects [male, n = 30; age 26.3 +/- 4.8 (SD) yr; body mass 78.8 +/- 13.1 kg] performed an isometric contraction of the knee extensors at 60 degrees of knee flexion, a quick stretch was imposed with a 12 degrees -step displacement at 100 degrees /s. The test was performed at 10 isometric activation levels ranging from 1.7 to 95.2% of maximal voluntary contraction (MVC). A strong linear relationship was observed between the peak imposed eccentric moment derived from quick stretch and the isometric activation level (y = 1.44x + 7.08; r = 0.99). This increase in the eccentric moment is consistent with an actomyosin-dependent elasticity located in series with the contractile element of muscle. By extrapolating the linear relationship to 100% MVC, the predicted maximum eccentric moment was found to be 151% MVC, consistent with in vitro data. A maximal voluntary, knee extensor strength test was also performed (5-95 degrees, 3 repetitions, +/-50, 100, 150, 200, and 250 degrees/s). The predicted maximum eccentric moment was 206% of the angle- and velocity-matched, maximal voluntary eccentric moments. This was attributed to a potent neural regulatory mechanism that limits the recruitment and/or discharge of motor units during maximal voluntary eccentric contractions.
منابع مشابه
Effects of Concentric and Eccentric Strength Training on Electromyography Activity of the Knee Agonist –Antagonist Muscle
Purpose: An appropriate activity of the knee agonist -antagonist muscles is important to resist against abnormal abduction-adduction moments loads around knee joint and reduce the risk of knee injuries. Exercise training has been commonly used as an intervention to improve neuromuscular activity within the synergic and/or agonist-antagonist muscles. However, maximizing the effectiveness of exer...
متن کاملEffect of eccentric exercise-induced muscle damage on electro-myographyic activity of quadriceps in untrained healthy females
Background: The aim of this study was to investigate muscle damage indicators and electromyography activities of quadriceps muscles at 25° of hip flexion in untrained healthy females after an eccentric exercise induced muscle fiber damage. Methods : A total of 14 healthy females participated in this pre-experimental study. The subjects performed maximal eccentric quadriceps contractions at ...
متن کاملBlockade of TNF in vivo using cV1q antibody reduces contractile dysfunction of skeletal muscle in response to eccentric exercise in dystrophic mdx and normal mice.
This study evaluated the contribution of the pro-inflammatory cytokine, tumour necrosis factor (TNF) to the severity of exercise-induced muscle damage and subsequent myofibre necrosis in mdx mice. Adult mdx and non-dystrophic C57 mice were treated with the mouse-specific TNF antibody cV1q before undergoing a damaging eccentric contraction protocol performed in vivo on a custom built mouse dynam...
متن کاملExperimental investigation of octagonal partially encased composite columns subject to concentric and eccentric loading
Partially Encased Composite (PEC) column is one of the recent achievements in the field of composite columns. This paper presents a combined experimental and theoretical study on the mechanical performances of six octagonal PEC columns subjected to axial compressive and bending moment loading. The major different between them was the concrete reinforcement details. The parameters studied in the...
متن کاملNumerical and Experimental Investigations on the Behavior of Steel-reinforced Concrete Columns Subjected to Eccentric Loading
Steel-reinforced concrete (SRC) columns, which are classified as composite columns, became the most widely used in recent years; because of their extensive advantages over the reinforced concrete and the steel columns. In this paper, the ductility index and its influential factors were explored to investigate the behavior of SRC columns. A straightforward approach was then proposed by establish...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 83 1 شماره
صفحات -
تاریخ انتشار 1997