Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration.

نویسندگان

  • Hersh Chandarana
  • Tobias K Block
  • Andrew B Rosenkrantz
  • Ruth P Lim
  • Danny Kim
  • David J Mossa
  • James S Babb
  • Berthold Kiefer
  • Vivian S Lee
چکیده

OBJECTIVE : To compare free-breathing radially sampled 3D fat suppressed T1-weighted gradient-echo acquisitions (radial volumetric interpolated breath-hold examination [VIBE]) with breath-hold (BH) and free-breathing conventional (rectilinearly sampled k-space) VIBE acquisitions for postcontrast imaging of the liver. MATERIALS AND METHODS : Eighteen consecutive patients referred for clinically indicated liver magnetic resonance imaging were imaged at 3 T. Three minutes after a single dose of gadolinium contrast injection, free-breathing radial VIBE, BH VIBE, and free-breathing VIBE with 4 averages were acquired in random order with matching sequence parameters. Radial VIBE was acquired with the "stack-of-stars" scheme, which uses conventional sampling in the slice direction and radial sampling in-plane.All image data sets were evaluated independently by 3 radiologists blinded to patient and sequence information. Each reader scored the following parameters: overall image quality, respiratory motion artifact, pulsation artifact, liver edge sharpness, and hepatic vessel clarity using a 5-point scale, with the highest score indicating the most optimum examination. Mixed model analysis of variance was used to compare sequences in terms of each measure of image quality. RESULTS : When scores were averaged over readers, there was no statistically significant difference between radial VIBE and BH VIBE regarding overall image quality (P = 0.1015), respiratory motion artifact (P = 1.0), and liver edge sharpness (P = 0.2955). Radial VIBE demonstrated significantly lower pulsation artifact (P < 0.0001), but had lower hepatic vessel clarity (P = 0.0176), when compared with BH VIBE. Radial VIBE had significantly higher image quality scores for all parameters when compared with free-breathing VIBE (P < 0.0001). Acquisition time for BH VIBE was 14 seconds and that of free-breathing radial VIBE and conventional VIBE with multiple averages was 56 seconds each. CONCLUSION : Radial VIBE can be performed during free breathing for contrast-enhanced imaging of the liver with comparable image quality to BH VIBE. However, further work is necessary to shorten the acquisition time to perform dynamic imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: preliminary observations.

OBJECTIVE The purposes of this study were to evaluate the feasibility of a free-breathing 3D gradient-recalled echo sequence with radial data sampling (radial 3D GRE) in abdominal MRI compared with a standard 3D GRE volumetric interpolated breath-hold examination (VIBE) sequence for imaging of cooperative patients and to perform a preliminary assessment in imaging of noncooperative patients. ...

متن کامل

Spectral Adiabatic Inversion Recovery (SPAIR) MR imaging of the Abdomen

Magnetic resonance imaging (MRI) has become a major imaging tool for the depiction and characterization of abdominal disease. Standard abdominal MRI protocols encompass different forms of T1-weighted (T1w) and T2-weighted (T2w) data acquisition. These sequences can be collected in less than 20 seconds, which typically is within the patients’ ability to suspend respiration. Hence, artifacts due ...

متن کامل

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla.

BACKGROUND The breathhold contrast-enhanced three-dimensional magnetic resonance angiography (MRA) using T1-weighted gradient-echo imaging sequence is the standard technique for MRA of the thorax. However, this technique is not desirable for certain patients with respiratory insufficiency, serious renal impairment, or allergy to contrast agents. The objective of this study was to optimize and e...

متن کامل

Head and neck paragangliomas: improved tumor detection using contrast-enhanced 3D time-of-flight MR angiography as compared with fat-suppressed MR imaging techniques.

BACKGROUND AND PURPOSE MR imaging techniques have proved their efficacy in imaging the head and neck region. In this study, we compared T1-weighted, dual T2-weighted, and fat-suppressed MR imaging and unenhanced and contrast-enhanced 3D time-of-flight MR angiography sequences for detection of head and neck paragangliomas. METHODS Thirty-one patients with 70 paragangliomas were examined. Four ...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 46 10  شماره 

صفحات  -

تاریخ انتشار 2011