Electrothermal atomic absorption spectrometric determination of aluminum: elimination of serum matrix effects.

نویسندگان

  • H J Gitelman
  • F R Alderman
چکیده

An improved electrothermal atomic absorption spectrometric method for determination of aluminum in serum is described. An ammonium hydroxide/sulfuric acid diluent is used to control matrix effects from serum constituents. Because serum produces no apparent matrix effects with this diluent, one can accurately calibrate the procedure with aqueous standards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved determination of aluminum in serum by electrothermal atomic absorption spectrophotometry.

This method for determining aluminum in human serum involves electrothermal atomic absorption spectrophotometry. A longer drying time allows less pre-dilution of the sample, and the method also includes a flush cycle after atomization. Standard-addition methodology is used to eliminate matrix effects and the need for a standard curve. We used this method on serum from 50 normal persons and from...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Electrothermal atomic absorption spectrometric determination of aluminum in serum with a new technique for protein precipitation.

We have studied the electrothermal atomic absorption measurement of aluminum in serum samples by direct analysis with standard additions and the use of a matrix modifier. We have also measured aluminum by analysis of the supernate after pretreatment of serum with concentrated nitric acid to precipitate proteins, and have compared the results obtained by these two techniques. Both appear to elim...

متن کامل

Kinetic fluorometric determination of aluminum in serum.

We describe a simple fluorometric method for determining aluminum in serum samples by monitoring the rate of reaction of 2-hydroxy-1-naphthaldehyde-p-methoxybenzoylhydrazone with aluminum ions. The emission of the resulting fluorescent metal-chelate formed is measured at 475 nm. Aluminum was measured in the supernate of serum after proteins were removed by precipitation with concentrated nitric...

متن کامل

Determination of nickel in biological samples prepared by microwave dissolution using electrothermal atomic absorption spectrometry after extraction with l,Sbis[phenyl-( 2-pyridyl) methylene] thiocarbonhydrazide

An electrothermal atomization atomic absorption spectrometric method for the determination of traces of nickel atIer extraction of the metal into methyl isobutyl ketone containing 1,5-bis[phenyl(2-pyridylhnethylene] thiocarbonhydrazide is suggested. The chief advantage of the method lies in its maximum allowable aqueous-to-organic phase volume ratio of 37. The method was applied to the determin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 7  شماره 

صفحات  -

تاریخ انتشار 1989