CINE Images of a Beating Rodent Cardiac Phantom
نویسندگان
چکیده
Methods A phantom was built consisting of a single walled chamber with similar axial dimensions to a rat left ventricle. The phantom wall is made from polyvinyl alcohol cryogel (PVAC). The phantom is housed in a sealed polypropylene tube in a water bath. An inlet/outlet hose is used to drive expansion of the phantom, a second outlet allows space for this expansion. The phantom is expanded by a gear pump located 1.2m from the magnet bore, driven by a sinusoidal waveform from an arbitrary waveform generator. A triggering pulse was also produced to trigger signal acquisition. The magnitude of the driving waveform was calibrated using ultrasonic M-mode images to give a cross-section ejection fraction of 60%.
منابع مشابه
Cine CT for attenuation correction in cardiac PET/CT.
UNLABELLED In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the at...
متن کاملDevelopment and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging
The increasing availability of rodent models of human cardiovascular disease has led to a need to translate noninvasive imaging techniques such as magnetic resonance imaging (MRI) from the clinic to the animal laboratory. The aim of this study was to develop phantoms simulating the short-axis view of left ventricular motion of rats and mice, thus reducing the need for live animals in the develo...
متن کاملDynamic organ modeling for minimally-invasive cardiac surgery
While most currently available minimally invasive robotically assisted cardiac surgical systems do not employ 3D image guidance, such support can be generated using pre operative images such as CT. Previously we demonstrated a virtual model of the thorax with simulated surgical instruments, and a pulsating virtual model of the coronary arteries. In this paper we report the overlay of optical en...
متن کاملFully-automatic synthesis of cine viability CMR images with minimal estimation error
Background A typical CMR exam includes cine, tagging, and delayed-hyperenhancement (DHE) sequences to produce images for evaluating global heart function, myocardial contractility, and viability, respectively. Usually, DHE imaging is conducted at mid-diastole. Nevertheless, obtaining cine DHE images is appealing to obtain simultaneous information about tissue viability and wall motion abnormali...
متن کاملEvaluation of a commercial cardiac motion phantom for dual‐energy chest radiography
Misregistration due to cardiac motion causes artifacts in two-exposure dual-energy subtraction images, in both the soft-tissue-only image and the bone-only image. Two previous investigations have attempted to avoid misregistration artifacts by using cardiac gating of the first and second exposures. The severity of misregistration was affected by the heart rate, the time interval between the low...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009