Use of volumetric modulated arc radiotherapy in patients with early stage glottic cancer.

نویسندگان

  • Banu Atalar
  • Gorkem Gungor
  • Hale Caglar
  • Gokhan Aydin
  • Bulent Yapici
  • Enis Ozyar
چکیده

AIMS AND BACKGROUND We compared conformal, intensity-modulated radiotherapy (IMRT) and intensity-modulated arc therapy (IMAT) in early stage glottic cancer in terms of dosimetric features as target coverage, dose to the organs at risk and total treatment time. METHODS AND MATERIALS Five consecutive T1 glottic squamous cell carcinoma patients were selected for the study. Three-dimensional conformal radiotherapy (3D-CRT), 3-field or 5-field intensity-modulated radiotherapy (3F-IMRT and 5F-IMRT), or IMAT, which was in 2 different forms--a regular IMAT (R-IMAT) and an alternative IMAT (A-IMAT) with an unirradiated section, was planned for each patient. The prescribed dose was 63 Gy in 28 fractions. The minimum dose for 95% of the clinical target volume (D95), maximum dose point at clinical target volume (Dmax), total monitor units, left and right carotid artery doses (V35 and V50 - percentage of volume receiving 35 Gy and 50 Gy), and total treatment time were calculated for each plan. RESULTS Median D95 values in the 5 plans studied with each technique ranged between 63 and 63.3 Gy (P = NS). Median Dmax values for each technique ranged between 65.4 and 70.8 Gy. The number of hot spots with IMRT and IMAT was significantly higher than with 3D-CRT plans. Conformal radiotherapy plans median V35 (93.6%) and V50 (76.6-83.3%) values for carotid arteries were significantly higher than with IMRT and IMAT (2.9%-11.4% and 0.0%). Average treatment times for 3D-CRT, 3F-IMRT, 5F-IMRT, R-IMAT and A-IMAT techniques were calculated as 64, 119, 147, 39 and 32 seconds, respectively. CONCLUSIONS IMAT has significantly decreased the treatment time compared to IMRT and 3D-CRT with acceptable homogeneous clinical target volume coverage and low carotid dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer

Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...

متن کامل

Volumetric modulated arc radiotherapy sparing the thyroid gland for early-stage glottic cancer: A dosimetrical analysis

Previous studies on advanced radiotherapy (RT) techniques for early stage glottic cancer have focused on sparing the carotid artery. However, the aim of the present study was to evaluate the dosimetric advantages of volumetric modulated arc therapy (VMAT) in terms of sparing the thyroid gland in early-stage glottic cancer patients. In total, 15 cT1N0M0 glottic cancer patients treated with defin...

متن کامل

Volumetric modulated arc therapy for carotid sparing in the management of early glottic cancer

PURPOSE Radiotherapy of the neck is known to cause carotid artery stenosis. We compared the carotid artery dose received between volumetric modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (IMRT) plans in patients with early glottic cancer. MATERIALS AND METHODS Twenty-one early glottic cancer patients who previously underwent definitive radiotherapy ...

متن کامل

Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...

متن کامل

Carotid sparing intensity modulated radiotherapy on early glottic cancer: preliminary study

PURPOSE To compare the dose distribution between carotid sparing intensity modulated radiotherapy (IMRT) and opposed lateral field technique (LAFT), and to determine the effects of carotid sparing IMRT in early glottic cancer patients who have risk factors for atherosclerosis. MATERIALS AND METHODS Ten early glottic cancer patients were treated with carotid sparing IMRT. For each patient, the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Tumori

دوره 98 3  شماره 

صفحات  -

تاریخ انتشار 2012