Predictors of outcomes in low-flow, low-gradient aortic stenosis: results of the multicenter TOPAS Study.

نویسندگان

  • Marie-Annick Clavel
  • Christina Fuchs
  • Ian G Burwash
  • Gerald Mundigler
  • Jean G Dumesnil
  • Helmut Baumgartner
  • Jutta Bergler-Klein
  • Rob S Beanlands
  • Patrick Mathieu
  • Julien Magne
  • Philippe Pibarot
چکیده

BACKGROUND Patients with low-flow, low-gradient aortic stenosis have a poor prognosis with conservative therapy but a high operative mortality if treated surgically. Recently, we proposed a new index of aortic stenosis severity derived from dobutamine stress echocardiography, the projected aortic valve area at a normal transvalvular flow rate, as superior to other conventional indices to differentiate true-severe from pseudosevere aortic stenosis. The objective of this study was to identify the determinants of survival, functional status, and change in left ventricular ejection fraction during follow-up of patients with low-flow, low-gradient aortic stenosis. METHODS AND RESULTS One hundred one patients with low-flow, low-gradient aortic stenosis (aortic valve area </=1.2 cm(2), left ventricular ejection fraction </=40%, and mean gradient </=40 mm Hg) underwent dobutamine stress echocardiography and an assessment of functional capacity using the Duke Activity Status Index. A subset of 72 patients also underwent a 6-minute walk test. Overall survival was 70+/-5% at 1 year and 57+/-6% at 3 years. After adjusting for age, gender, and the type of treatment (aortic valve replacement versus no aortic valve replacement), significant predictors of mortality during follow-up were a Duke Activity Status Index </=20 (P=0.0005) or 6-minute walk test distance </=320 m (P<0.0001, in the subset of 72 patients), projected aortic valve area at a normal transvalvular flow rate </=1.2 cm(2) (P=0.03), and peak dobutamine stress echocardiography left ventricular ejection fraction </=35% (P=0.03). More severe stenosis, defined as projected aortic valve area </=1.2 cm(2), was a predictor of mortality only in the no aortic valve replacement group. The Duke Activity Status Index, 6-minute walk test, and left ventricular ejection fraction improved significantly during follow-up in the aortic valve replacement group, but remained unchanged or decreased in the no aortic valve replacement group. CONCLUSIONS In patients with low-flow, low-gradient aortic stenosis, the most significant risk factors for poor outcome were (1) impaired functional capacity as measured by Duke Activity Status Index or 6-minute walk test distance; (2) more severe valve stenosis as measured by projected aortic valve area at a normal transvalvular flow rate; and (3) reduced peak stress left ventricular ejection fraction, a composite measure accounting for both resting left ventricular function and contractile reserve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac manifestation of hepatocellular carcinoma.

C et al. Influence of pre-operative left ventricular contractile reserve on postoperative ejection fraction in low-gradient aortic stenosis. Outcome after aortic valve replacement for low-flow/low-gradient aortic stenosis without contractile reserve on dobutamine stress echocardiography.dictors of outcomes in low-flow, low-gradient aortic stenosis: results of the multi-center TOPAS Study. B-typ...

متن کامل

Two-dimensional strain for the assessment of left ventricular function in low flow-low gradient aortic stenosis, relationship to hemodynamics, and outcome: a substudy of the multicenter TOPAS study.

BACKGROUND Decision making in patients with low flow-low gradient aortic stenosis mainly depends on the actual stenosis severity and left ventricular function, which is of prognostic importance. We used 2-dimensional strain parameters measured by speckle tracking at rest and during dobutamine stress echocardiography to document the extent of myocardial impairment, its relationship with hemodyna...

متن کامل

Projected valve area at normal flow rate improves the assessment of stenosis severity in patients with low-flow, low-gradient aortic stenosis: the multicenter TOPAS (Truly or Pseudo-Severe Aortic Stenosis) study.

BACKGROUND We sought to investigate the use of a new parameter, the projected effective orifice area (EOAproj) at normal transvalvular flow rate (250 mL/s), to better differentiate between truly severe (TS) and pseudo-severe (PS) aortic stenosis (AS) during dobutamine stress echocardiography (DSE). Changes in various parameters of stenosis severity have been used to differentiate between TS and...

متن کامل

B-type natriuretic peptide in low-flow, low-gradient aortic stenosis: relationship to hemodynamics and clinical outcome: results from the Multicenter Truly or Pseudo-Severe Aortic Stenosis (TOPAS) study.

BACKGROUND The prognostic value of B-type natriuretic peptide (BNP) is unknown in low-flow, low-gradient aortic stenosis (AS). We sought to evaluate the relationship between AS and rest, stress hemodynamics, and clinical outcome. METHODS AND RESULTS BNP was measured in 69 patients with low-flow AS (indexed effective orifice area < 0.6 cm2/m2, mean gradient < or = 40 mm Hg, left ventricular ej...

متن کامل

Aortic valve replacement for low-flow/low-gradient aortic stenosis operative risk stratification and long-term outcome: a European multicenter study.

OBJECTIVES We evaluated a large multicenter series of patients operated on for low-flow/low-gradient aortic stenosis (LF/LGAS) to stratify the operative risk, assess whether perioperative mortality has decreased over recent years, and analyze the post-operative outcome. BACKGROUND Although LF/LGAS is classically associated with a high operative risk, few data are available concerning the resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 118 14 Suppl  شماره 

صفحات  -

تاریخ انتشار 2008