Cryogenic colocalization microscopy for nanometer-distance measurements.

نویسندگان

  • Siegfried Weisenburger
  • Bo Jing
  • Dominik Hänni
  • Luc Reymond
  • Benjamin Schuler
  • Alois Renn
  • Vahid Sandoghdar
چکیده

The main limiting factor in spatial resolution of localization microscopy is the number of detected photons. Recently we showed that cryogenic measurements improve the photostability of fluorophores, giving access to Angstrom precision in localization of single molecules. Here, we extend this method to colocalize two fluorophores attached to well-defined positions of a double-stranded DNA. By measuring the separations of the fluorophore pairs prepared at different design positions, we verify the feasibility of cryogenic distance measurement with sub-nanometer accuracy. We discuss the important challenges of our method as well as its potential for further improvement and various applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nanometer distance measurements between multicolor quantum dots.

Quantum dot dimers made of short double-stranded DNA molecules labeled with different color quantum dots at each end were imaged using multicolor stage-scanning confocal microscopy. This approach eliminates chromatic aberration and color registration issues usually encountered in other multicolor imaging techniques. We demonstrate nanometer accuracy in individual distance measurement by suppres...

متن کامل

Nanometer-localized multiple single-molecule fluorescence microscopy.

Fitting the image of a single molecule to the point spread function of an optical system greatly improves the precision with which single molecules can be located. Centroid localization with nanometer precision has been achieved when a sufficient number of photons are collected. However, if multiple single molecules reside within a diffraction-limited spot, this localization approach does not w...

متن کامل

Origins of nanoscale damage to glass-sealed platinum electrodes with submicrometer and nanometer size.

Glass-sealed Pt electrodes with submicrometer and nanometer size have been successfully developed and applied for nanoscale electrochemical measurements such as scanning electrochemical microscopy (SECM). These small electrodes, however, are difficult to work with because they often lose a current response or give a low SECM feedback in current-distance curves. Here we report that these problem...

متن کامل

Statistical tests for measures of colocalization in biological microscopy.

Colocalization analysis is the most common technique used for quantitative analysis of fluorescence microscopy images. Several metrics have been developed for measuring the colocalization of two probes, including Pearson's correlation coefficient (PCC) and Manders' correlation coefficient (MCC). However, once measured, the meaning of these measurements can be unclear; interpreting PCC or MCC va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemphyschem : a European journal of chemical physics and physical chemistry

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2014