Radiation Monitoring Experiment Using Thermoluminescent Dosimeter for the Tr 19 Cyclotron Area in Nuclear Research Institute

نویسندگان

  • A. STOCHIOIU
  • L. CRACIUN
  • F. MIHAI
  • I. TUDOR
چکیده

The core of Radiopharmaceuticals Research Centre, CCR, is represented by a TR19 cyclotron (Advanced Cyclotron Systems Inc.), a versatile and fully automated and computer controlled machine. This cyclotron accelerates negative ions (H), on a vertically arranged plane, up to 19 MeV energy, and is provided with two external beam lines and dual extraction capabilities. The main use is for the production of positron emitting radionuclide namely F, O, N and C. The pharmaceuticals labeled with these radioisotopes are used for positron emission tomography (PET) imaging. The radiation levels were measured in the facility at different locations namely cyclotron vault, control console, radiochemistry laboratory, beam extension room and the stack using a comprehensive computerized monitoring system. The thermoluminescent dosimeter, TLD, LiF: Mg, Cu, P are commonly used for the radiation dose measurements to determine the ambient dose equivalent, which are part of passive systems of environmental radioactivity monitoring. In this work TLD were distributed for a period of 87 days in 12 points of interest according to the map of the cyclotron area and were read out to determine the corresponding activities. All measured values were higher than those obtained in IFIN-HH nuclear research units so, at cyclotron vault point the ambient dose equivalent rate was 56 695 nSv/h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

6 th Workshop on Radiation Monitoring for the International Space

Preliminary TLD results from the DOSMAP experiment on ISS G. Reitz, S. Deme, I. Apathy 1 German Aerospace Center (DLR), Cologne, Germany 2 KFKI Atomic Energy Research Institute, Budapest, Hungary Abstract: The Dosimetric Mapping (DOSMAP) experiment, operated by Expedition Two onboard the ISS attempted to record and map radiation inside Space Station within a four month period. One of the severa...

متن کامل

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Production and quality control of 82mRb and primary PET scans using its radiopharmaceutical for heart examinations [Persian]

According to the importance of positron emitters in nuclear medicine, 82mRb was produced as a member of this group of radiopharmaceuticals. After being converted into an injectable form, enough information was provided for imaging with this radiopharmaceutical. 82mRb with high radioisotopic purity and half-life of 6.5 hours, in chloride form, can be considered as a suitable positron emitt...

متن کامل

Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran

Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016