Hip screw lateral migration with no cut-out or non-union implication: a case report
نویسندگان
چکیده
Hip screw migration of peritrochanteric fracture fixation devices is a described complication in English literature. Medial migration occupies the majority of these cases whereas lateral migration is rare. We report the case of an 85-year-old woman whose intramedullary osteosynthesis of a trochanteric fracture was complicated by hip screw lateral migration. Mobilization was not influenced and no cut-out or non-union was detected. The migrated hip screw was easily removed and the discomfort vanished. The need for adequate surgical technique and radiographic examination after re-injuries even if the patient remains ambulatory is emphasised.
منابع مشابه
بررسی کاربرد Short barrel DHS در درمان شکستگی انترتروکانتریک
Cut out or extrusion of the lag screw from the superior aspect of head and neck of the femur is one of the most common and devastating complications of the surgery of the intertrochanteric fractures with DHS. The exact cause of this complications is unknown, but it seems to be related to osteopenia, inappropriate position of lag screw inside head of the femur and inability of DHS to slide insid...
متن کاملA case report of Progressive subluxation leading to an anterior dislocation of the hip following sliding hip screw fixation for pertrochanteric Extracapsular 4 part fracture neck of femur
Unstable 4 part pertrochanteric fractures without lateral cortical support presents considerable technical problem in treatment with high risk of failure with any implant. Anatomical or slight valgus reduction and subchondral central position of the lag screw (TAD <25 mm) reduces the chance of screw cut out and other complications.
متن کاملRadiological and functional outcome in unstable, osteoporotic trochanteric fractures stabilized with dynamic helical hip system
A dynamic hip screw (DHS) remains the implant of choice for stabilization of trochanteric fractures because of its favourable results and low rate of non-union or hardware failure, but complication rates of the DHS are higher in unstable and osteoporotic trochanteric fractures. The proponents of the dynamic helical hip system (DHHS) report that it has the potential to decrease the cut-out rates...
متن کاملComparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
BACKGROUND Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evalua...
متن کاملAugmentation of proximal femoral nail in unstable trochanteric fractures
INTRODUCTION Biomechanically proximal femoral nail (PFN) is a better choice of implant, still it is associated with screw breakage, cut out of screw through femoral head, Z effect, reverse Z effect, and lateral migration of screws. The purpose of this study is to evaluate the results of augmented PFN in terms of prevention of postoperative complications and failure rates in unstable trochanteri...
متن کامل