Hydrogen ion-selective poly(vinyl chloride) membrane electrode based on a calix[4]arene.

نویسندگان

  • Demet Kuruoğlu
  • Esin Canel
  • Shahabuddin Memon
  • Mustafa Yilmaz
  • Esma Kiliç
چکیده

A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selectivity with respect to lithium, sodium and potassium, and characteristics similar to those reported for the conventional pH glass membrane electrode. It can be used as a potentiometric indicator electrode in hydrofluoric acid solutions. The effects of iodide, thiocyanate, perchlorate and bromide on the characteristics of the electrode were also considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Discrimination of methylammonium from organic ammonium ions using ion-selective electrodes based on calix[4]arene-crown-6 conjugates.

Calix[4]-bis-2,3-naphtho-crown-6 can be used to discriminate between methylammonium and other organic ammonium ions. An electrode based on this ionophore, potassium tetrakis(p-chlorophenyl)borate (20 mol% relative to the ionophore) as an ionic additive and bis(2-ethylhexyl) sebacate as a solvent mediator in a poly(vinyl chloride) membrane matrix, displayed higher selectivity for methylammonium ...

متن کامل

Chromium (III) ion selective electrode based on di(benzylamino)glyoxime

A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of

متن کامل

Comparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques

Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

متن کامل

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

Determination of the pH difference across a cell membrane using a methylammonium-selective membrane electrode.

A method was developed for determining pH differences across cell membranes using a methylammonium-selective membrane electrode, based on monitoring of the pH gradient-induced uptake of methylammonium in situ. The methylammonium electrode was constructed using calix[6]arene-hexaacetic acid hexaethyl ester as a neutral carrier and bis(2-ethylhexyl) sebacate as a membrane solvent in a poly(vinyl ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 2  شماره 