Numerical Investigation into Effects of a Receive Array on SAR in MRI

نویسندگان

  • Z. Wang
  • J. Jin
  • C. M. Collins
  • S. Zhao
  • S. Oh
  • Q. X. Yang
  • F. J. Robb
چکیده

Introduction Currently, the "hybrid" coil system, consisting of a large birdcage coil for transmission and multi-element array as the receive coil, is widely used in clinical MRI. This design can acquire images with short acquisition time and high SNR, and has particular advantage in parallel imaging. However, relatively little research is focused on safety in the "hybrid" coil environment. In this work, numerical calculation is adopted to investigate SAR variation in the human body models due to loading/unloading a twelve-channel torso coil. Methods Three-dimensional anatomical models NORMAN and NAOMI [1,2] were obtained from the Health Protection Agency (HPA, UK). Originally, NORMAN has a size of 277x148x871 at 2mm isometric resolution and 37 tissue types and NAOMI has a size of 294x124x791 at 2mm isometric resolution and 40 tissue types. They were resampled to 5x5x5mm and adapted to commerciallyavailable finite-difference time-domain software “xFDTD” (REMCOM; State College, PA). The dielectric values of the tissues were taken from http://niremf.ifac.cnr.it/tissprop. For this study, a 16-rung body size (61 cm coil diameter and 62 cm length, 66cm shield diameter and 122 cm length, as in a GE Signa 1.5T system) high-pass birdcage coil was modeled at 64MHz. With the torso coil (six anterior and six posterior elements each with a size of 240x180mm) in the center of the birdcage coil, one clinical configuration is considered. The coil geometry and the human body models are shown in Fig.1. The torso coil model included coil elements, cables, blocking networks, cable baluns (traps), and feeding board etc as a holistic system. At first, field calculations were performed with the human body and birdcage coil only. The coil was driven with 32 current sources which were placed in the middle of end-ring elements and a 22.5-degree phase-shift was set between adjacent rungs. This method has shown practically identical results to driving the coil on resonance in quadrature at either two or four locations up to 128 MHz [3]. Second, the results were normalized to the whole body average SAR=2W/kg (based on IEC regulatory limits [4]). Then, the current source amplitude values were updated and the torso coil was also loaded to run the model again. Finally, the SAR variation between these two cases was examined. Results & Discussion NORMAN and NAOMI have different SAR distributions since they have different mass, shape, organ geometry and the absorption power. Local SAR values are higher in the peripheral area of the body in both models as previously predicted. The SAR distributions on the coronal and sagittal planes passing through the center of the heart are shown in Fig. 2. From the calculation, the whole body average SAR of NORMAN is increased to 2.14W/kg while the value for NAOMI is increased to 2.18W/kg when the torso coil is loaded compared to 2.0 W/kg when the coil is absent. During RF transmission, the induced voltages drop on blocking circuits, baluns and cable traps of the coil elements and significantly alter the local field distribution, therefore increasing the whole body average SAR. The higher SAR value of NAOMI is probably because the cable is closer to the right leg of NAOMI and the cable length is also longer to avoid contact of the cable wire with tissues. However, both increases are less than 10% and maximum one-cell SAR rise is from 20.68W/Kg to 22.83W/Kg(2.15W/Kg increment, approximately 10%). Thus, under normal conditions it appears that the torso coil does not change SAR by more than 10%. The difference of SAR distribution with/without torso coil is shown in Fig.3 at the central coronal and sagittal plane. There is a pronounced effect in the area of the coccyx in both models due to effects from the feeding board. Reference [1] P. Dimbylow, Phy. Med. Bio. 1997;42: 479-490 [2] P. Dimbylow, Phy. Med. Bio. 2005;50:1047-1070 [3] W. Liu et al. Appl. Magn. Reson. 2005;29:5-18 [4] IEC 60601-2-33, 2006-02

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of a Receive-array Coil on Specific Absorption Rate at 3T: Simulations and Experiments with Basic Geometries

Introduction: Receive-only (Rx) phased-array coils are used routinely in clinical situations for a number of purposes including achieving higher SNR [1] and shorter imaging times [2], but how their presence affects the RF field distribution during transmission is not routinely considered. At a minimum, the receive array introduces highly conductive surfaces with their associated boundary condit...

متن کامل

SAR Investigation of Array Antennas for Mobile Handsets

The peak SAR values of two-element array antennas for mobile handsets in the vicinity of a spherical phantom of a human head are evaluated numerically as a function of the distance between the array antenna and the head phantom when the two elements of a two-element array antenna are either co-phase voltage-fed or reverse-phase voltage-fed. It is found that relation between the worst case of th...

متن کامل

Investigation of Wavenumber Domain Imaging Algorithm for Ground-Based Arc Array SAR

Ground-based synthetic aperture radar (GB-SAR) has become an important technique for remote sensing deformation monitoring. However, most of the existing GB-SAR systems realize synthetic aperture by exploiting two closely spaced horn antennas to move along a linear rail. In order to obtain higher data acquisition efficiency and a wider view angle, we introduce arc antenna array technology into ...

متن کامل

A numerical investigation into the crack effects on the natural frequencies of the plates

In the current study, the effect of such parameters as the length, position and angle of crack on free vibrations of a cracked plate was examined by finite element method. The assumed crack was internal and through and its growth was ignored. In the proposed finite element model, crack was considered as a discontinuity on the plate surface and the results were compared with the results of other...

متن کامل

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

A Numerical Investigation on Aerodynamic Coefficients of Solar Troughs Considering Terrain Effects and Vortex Shedding

Recently, increase in the cost of fossil fuels and taking into consideration the environmental effects of exploiting them, caused many researchers and governments to find some ways to make use of renewable energies more cost-effectively. Solar energy is a category of renewable energies which could be harvested via several technologies. One of the most practical methods is using parabolic trough...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008