3D nanogap interdigitated electrode array biosensors.
نویسندگان
چکیده
Three-dimensional interdigitated electrodes (IDEs) have been investigated as sensing elements for biosensors. Electric field and current density were simulated in the vicinity of these electrodes as a function of the electrode width, gap, and height to determine the optimum geometry. Both the height and the gap between the electrodes were found to have significant effect on the magnitude and distribution of the electric field and current density near the electrode surface, while the width of the electrodes was found to have a smaller effect on field strength and current density. IDEs were fabricated based on these simulations and their performance tested by detecting C-reactive protein (CRP), a stress-related protein and an important biomarker for inflammation, cardiovascular disease risk indicator, and postsurgical recuperation. CRP-specific antibodies were immobilized on the electrode surface and the formation of an immunocomplex (IC) with CRP was monitored. Electrochemical impedance spectroscopy (EIS) was employed as the detection technique. EIS data at various concentrations (1 pg/mL to 10 microg/mL) of CRP spiked in buffer or diluted human serum was collected and fitted into an equivalent electrical circuit model. Change in resistance was found to be the parameter most sensitive to change in CRP concentration. The sensor response was linear from 0.1 ng/mL to 1 microg/mL in both buffer and 5% human serum samples. The CRP samples were validated using a commercially available ELISA for CRP detection. Hence, the viability of IDEs and EIS for the detection of serum biomarkers was established without using labeled or probe molecules.
منابع مشابه
A planar interdigitated ring electrode array via dielectrophoresis for uniform patterning of cells.
Uniform patterning of cells is highly desirable for most cellular studies involving cell-cell interactions but is often difficult in an in vitro environment. This paper presents the development of a collagen-coated planar interdigitated ring electrode (PIRE) array utilizing positive dielectrophoresis to pattern cells uniformly. Key features of the PIRE design include: (1) maximizing length alon...
متن کاملNanogap field-effect transistor biosensors for electrical detection of avian influenza.
Field-effect transistor (FET)-type biosensors have shown potential for use in label-free electrical detection with high sensitivity. An ion-selective FET (ISFET) utilizes a reference electrode in the form of an aqueous solution. Its conductance is dependent on charged species on the surface of the ISFET. The sensitivity of nanowire FETs (NWFETs) is high enough to enable single-molecule detectio...
متن کاملAmperometric biosensor based on 3D ordered freestanding porous Pt nanowire array electrode.
A three-dimensionally (3D) ordered freestanding porous platinum (Pt) nanowire array electrode (PPNWAE) with pores of several nanometers in size and a Pt nanowire array electrode (PNWAE) without pores were facilely fabricated by metal electrodeposition and direct integration with a Pt disk electrode. The unusual PPNWAE with high active area showed excellent sensitivity (0.36 mA cm(-2) mM(-1)) an...
متن کاملNeuronal differentiation and synapse formation of PC12 and embryonic stem cells on interdigitated microelectrode arrays: contact structures for neuron-to-electrode signal transmission (NEST).
The development of neuron-microelectrode interfaces (neurochips) is highly desirable for the non-invasive recording of the cellular response to neuroactive drugs as well as the electrical stimulation of nervous tissue by implantable electrodes. A prerequisite for neuron-to-electrode signal transmission (NEST) is the formation of synapse-like contacts between the neuronal cell and the conductive...
متن کاملInfluence of droplet coverage on the electrochemical response of planar microelectrodes and potential solving strategies based on nesting concept
Recently, biosensors have been widely used for the detection of bacteria, viruses and other toxins. Electrodes, as commonly used transducers, are a vital part of electrochemical biosensors. The coverage of the droplets can change significantly based on the hydrophobicity of the microelectrode surface materials. In the present research, screen-printed interdigitated microelectrodes (SPIMs), as o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 397 4 شماره
صفحات -
تاریخ انتشار 2010