Impact of flattening-filter-free techniques on delivery time for lung stereotactic volumetric modulated arc therapy and image quality of concurrent kilovoltage cone-beam computed tomography: a preliminary phantom study
نویسندگان
چکیده
To the Editor, Volumetric modulated arc therapy (VMAT) serves as a means for stereotactic hypofractionated treatment of lung tumors [1]. The present authors proposed an efficient VMAT sequence by restricting leaf speeds of a multi-leaf collimator per gantry rotation angle to below 1 mm/degree, thereby reducing the dose delivery time down to 210 s for a D95 prescription dose of 50 Gy in four fractions [2, 3]. The authors also suggested further reduction of the dose delivery time to below 100 s using flattening-filter-free (FFF) techniques [3]. Recently we evaluated a non-clinical FFF research configuration by adding an FFF filter to our linac system, a Synergy with an MLCi multi-leaf collimator (Elekta AB, Stockholm, Sweden). The FFF filter is made of stainless steel and has a constant thickness of 2 mm for 6and 10-MV beams. Furthermore, we also tested a non-clinical on-board conebeam CT (CBCT) system, XVI 5.0 research version, that allows concurrent 4D CBCT imaging during VMAT delivery. It is anticipated that the reduced VMAT delivery time may degrade CBCT image quality due to a much lower number of projection images. The purposes of this study were: (i) to quantify the stereotactic lung VMAT delivery time with FFF, and (ii) to visually inspect CBCT image quality with FFF.
منابع مشابه
The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography
Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...
متن کاملStereotactic Body Radiotherapy for Small Lung Tumors in the University of Tokyo Hospital
Our work on stereotactic body radiation therapy (SBRT) for primary and metastatic lung tumors will be described. The eligibility criteria for SBRT, our previous SBRT method, the definition of target volume, heterogeneity correction, the position adjustment using four-dimensional cone-beam computed tomography (4D CBCT) immediately before SBRT, volumetric modulated arc therapy (VMAT) method for S...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملPhantom based kV-CBCT dose plan calculations for re-planning decision: comparison with CT-based dose plans
s 17th Annual SASRO Meeting, Davos 2013 Physics Oral P01-22 P01 Phantom based kV-CBCT dose plan calculations for re-planning decision: comparison with CT-based dose plans P01 P02 First experimental results of motion mitigation by continuous line scanning P02 P03 Impact of respiratory-correlated CT reconstruction algorithms in the choice of margin definition for free breathing lung treatment P03...
متن کاملMega Voltage Cone Beam Computed Tomography (MV- CBCT) using a Standard Medical Linear Accelerator and EPID: A feasibility study.
Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...
متن کامل