Safety and Efficacy of the Prostar XL Vascular Closing Device for Percutaneous Closure of Large Arterial Access Sites

نویسندگان

  • Christoph Thomas
  • Volker Steger
  • Stefan Heller
  • Martin Heuschmid
  • Dominik Ketelsen
  • Claus D. Claussen
  • Klaus Brechtel
چکیده

Purpose. The purpose of this study is to retrospectively evaluate the efficacy and safety of the Prostar XL device for percutaneous large access site closure in an unselected patient and operator collective. Materials and Methods. All patients (n = 50) who had received percutaneous vascular closing with the Prostar XL device in our institution with follow-up data of at least 6 months were retrospectively included. Primary (freedom from surgical conversion) and continued (freedom from groin surgery in further course) technical success and major (deviations from expected outcome requiring surgery) and minor (other deviations from expected outcome) complications were assessed. Success and complications rates were correlated with delivery system size (Mann-Whitney Rank Sum Tests) and operator experience (paired samples t-test). Results. Rates of primary and continued technical success as well as major and minor complications were 93.6%, 89.7%, 10.3%, and 10.3% (groin based) and 90.0%, 84.0%, 16.0%, and 16.0% (patient based), respectively. No correlation of success and complications rate was found with delivery system sizes and operator experience. Conclusions. Application of the Prostar XL device for percutaneous closure of large arterial access sites is safe with a relatively high rate of technical success and low rate of major complications. Sizes of the delivery systems and the experience of the operator did not influence the results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous repair of aortic aneurysms: a prospective study of suture-mediated closure devices.

PURPOSE To evaluate prospectively the safety and efficacy of totally percutaneous placement of abdominal and thoracic aortic endografts using the Prostar XL suture-mediated closure system. METHODS From January 2002 to January 2005, we attempted to insert percutaneously all bifurcated abdominal aortic and thoracic endografts. Consecutive patients (25 men, four women), with mean age 74.9 years ...

متن کامل

True percutaneous approach for transfemoral aortic valve implantation using the Prostar XL device: impact of learning curve on vascular complications.

OBJECTIVES The purpose of this study was to evaluate the incidence of vascular complications and the predictors of Prostar failure for a "true percutaneous approach" in transfemoral transcatheter aortic valve implantation (TAVI). BACKGROUND Safety and efficacy of a true percutaneous approach in transfemoral-TAVI has not been described in a large prospective cohort. METHODS Among 264 patient...

متن کامل

Percutaneous access and closure of femoral artery access sites associated with endoluminal repair of abdominal aortic aneurysms.

PURPOSE To report longer follow-up and further experience using the Prostar XL Percutaneous Vascular Surgery (PVS) device for access and closure of large bore femoral artery access sites during endovascular repair of abdominal aortic aneurysms (AAAs). METHODS One hundred forty-four patients (128 men; mean age 72 years, range 56-89) undergoing endovascular AAA repair had percutaneous access an...

متن کامل

Percutaneous closure devices for endovascular repair of infrarenal abdominal aortic aneurysms: a prospective, non-randomized comparative study.

PURPOSE This study was designed to describe and evaluate our preliminary results with a percutaneous arterial closure device as compared to those obtained with conventional femoral surgical cut down during endovascular repair of abdominal aortic aneurysms (AAA). MATERIAL AND METHODS Between January 2004 and December 2006, 40 of 86 AAA patients selected for endovascular repair met the criteria...

متن کامل

Percutaneous endovascular aortic aneurysm repair: a prospective evaluation of safety, efficiency, and risk factors.

PURPOSE To evaluate the efficiency of totally percutaneous endovascular aortic aneurysm repair in a large cohort of patients and to define risk factors for failure with a 10-F vascular closure system. METHODS A prospective study examined the feasibility and safety of percutaneous femoral artery closure with a single Prostar XL 10-F vascular closure device applied in conjunction with the precl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013