Equivalent Performance of the Cobas® Cdiff Test for Use on the Cobas® Liat® System and the Cobas® 4800 System
نویسندگان
چکیده
Clostridium difficile infection is a significant health burden, and innovative solutions are needed to shorten time to diagnosis and improve infection control. We evaluated the performance of the cobas® Cdiff test for use on the cobas® Liat® System (cobas® Liat® Cdiff), a single-sample, on-demand, and automated molecular solution with a 20-min turnaround time. The limit of detection was 45-90 colony-forming units (CFUs)/swab for toxigenic strains that covered the most prevalent toxinotypes, including the hyper-virulent epidemic 027/BI/NAP1 strain. Using 442 prospectively collected clinical stool specimens, we compared the performance of the cobas® Liat® Cdiff to direct culture and to the cobas® Cdiff test on the cobas® 4800 System (cobas® 4800 Cdiff) - a medium-throughput molecular platform. The sensitivity and specificity of the cobas® Liat® Cdiff compared to direct culture were 93.1% and 95.1%, respectively, and this performance did not statistically differ from the cobas® 4800 Cdiff (P < 0.05). Direct correlation of the cobas® Liat® and cobas® 4800 Cdiff tests yielded overall percent agreement of 98.6%. The test performance, automation, and turnaround time of the cobas® Liat® Cdiff enable its use for on-demand and out-of-hours testing as a complement to existing batch testing solutions like the cobas® 4800 Cdiff.
منابع مشابه
Multicenter Comparison Study of both Analytical and Clinical Performance across Four Roche Hepatitis C Virus RNA Assays Utilizing Different Platforms
The efficacy of antiviral treatment for chronic hepatitis C virus (HCV) infection is determined by measuring HCV RNA at specific time points throughout therapy using highly sensitive and accurate HCV RNA assays. This study compared the performances of two recently developed real-time PCR HCV RNA assays, cobas HCV for use on the cobas 6800/8800 systems (cobas 6800/8800 HCV) and cobas HCV for use...
متن کاملHigh-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas® CT/NG
We compared the analytical and clinical performance of cobas® CT/NG for use on the Cobas® 6800/8800 Systems with the Cobas® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Us...
متن کاملSwabs (dry or collected in universal transport medium) and semen can be used for the detection of Chlamydia trachomatis using the cobas 4800 system.
In this prospective study, the fully automated cobas 4800 CT/NG and the cobas TaqMan CT tests were compared for Chlamydia trachomatis detection in urine and in genital specimens collected with Copan flocked swabs in culture media. A protocol was also established for the highly sensitive detection of C. trachomatis in semen specimens using the cobas 4800 CT/NG test. A total of 708 consecutive ur...
متن کاملExtraction of Zn, Mn and Co from Zn-Mn-Co-Cd-Ni containing solution using D2EHPA, CYANEX® 272 and CYANEX® 302
Effects of pH, D2EHPA, Cyanex® 302 and Cyanex® 272 on extractions of zinc, manganese and cobalt from a Zn-Mn-Co-Cd-Ni containing solution was comprehensively investigated at the room temperature. The addition of Cyanex® 302 indicated a left-shifting-effect on the extraction curve of zinc, a right-shifting-effect on the extraction curve of manganese and no effect on the extraction of cobalt. The...
متن کاملSputasol (Dithiothreitol 0.54%) Improves the Detection of Human Papillomaviruses Using the Cobas 4800 System
Dear Editor, Persistent infection with human papillomavirus (HPV) is the main cause of cervical cancer. Screening of cervical specimens for high-risk human papillomaviruses (HR-HPV) has become a routine part of patient care in most countries. The Roche cobas 4800 system (Roche Molecular Systems Inc., Pleasanton, CA, USA), a fully automated system that uses in vitro qualitative realtime PCR tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2017