The Boston keratoprosthesis provides a wide depth of focus.
نویسندگان
چکیده
PURPOSE To measure the through-focus curve for eyes implanted with a type 1 Boston keratoprosthesis (KPro) and compare it to that of pseudophakic controls with fixed pupil sizes. The results should assist in evaluating postoperative visual quality after surgery. They should also help to determine the necessary KPro inventories in terms of refractive power steps. METHODS Autorefraction and manifest refraction were performed on all eyes. The monocular through-focus acuity curve was plotted in reference to the best-corrected visual acuity by spectacle plane defocus ranging from +5.00 to -5.00 dioptres in 0.50 dioptre increments. These measurements were obtained on KPro-implanted eyes, pseudophakic eyes as controls, and on the same control eyes after fixing the pupil diameter to 3 and 2 mm using black painted iris contact lenses. RESULTS Ten KPro eyes and five control eyes were included. Good agreement was noted between the subjective refractions and autorefraction in KPro eyes. The average through-focus curve for the control eyes was significantly steeper than that of the KPro curve, but became comparable after fixing the control pupil to 2 and 3 mm. CONCLUSION The KPro's wide depth-of-focus makes the visual acuity less dependent on an exact refractive correction at distance and explains the 'pseudoaccomodation' experienced by these patients. This is primarily due to the small pupil diameter of the KPro. The current manufacturing steps in 0.50 dioptre increments appears to be sufficient.
منابع مشابه
Results with the Boston Type I keratoprosthesis after Acanthamoeba keratitis
Purpose To report the outcomes of implantation of the Boston Type I keratoprosthesis in three patients with Acanthamoeba keratitis (AK), a severe infection that can lead to significant visual loss. Observations Case series reporting three patients with difficult cases of AK that needed multiple corneal transplantations and glaucoma surgeries. All patients were implanted with the Boston Type I...
متن کاملBoston type 1 keratoprosthesis: the university of california davis experience.
PURPOSE To compare the University of California Davis experience using the Boston keratoprosthesis with the Boston Keratoprosthesis Study Group's initial report. DESIGN Retrospective chart review. PARTICIPANTS We analyzed 30 eyes of 28 patients who previously underwent Boston type 1 keratoprosthesis surgery at our institution between 2004 and 2008. METHODS Preoperative, intraoperative, an...
متن کاملTreatment of Refractory Keratitis After a Boston Type I Keratoprosthesis With Corneal Collagen Cross-Linking.
PURPOSE To report a patient with refractory keratitis after a Boston type I keratoprosthesis treated with corneal collagen cross-linking (CXL). METHODS Case report. RESULTS A 29-year-old man with a history of chemical burn in the left eye underwent keratoprosthesis implantation. He developed infectious keratitis 4 months after surgery, which did not respond to topical antibiotics. The patie...
متن کاملAnterior Segment Optical Coherence Tomography for the Quantitative Evaluation of the Anterior Segment Following Boston Keratoprosthesis
OBJECTIVE To quantitatively evaluate the anterior segment using anterior segment optical coherence tomography (AS-OCT) following Boston keratoprosthesis type 1. METHODS A retrospective study consisted of AS-OCT imaging at a single time point postoperatively in 52 eyes. Main outcomes measures include anatomical and functional anterior chamber depth (ACD), angle (ACA) and peripheral and proxima...
متن کاملImproved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue
The type 1 Boston Keratoprosthesis preparation requires a 3-mm central punch and an 8.5 mm or larger punch in the carrier tissue. These punches are ideally concentric, but we have found difficulty in achieving concentric punches when the larger punch is performed first. We present a modification in the preparation procedure to help minimize centration error.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians
دوره 35 1 شماره
صفحات -
تاریخ انتشار 2015