False-negative responses in glaucoma perimetry: indicators of patient performance or test reliability?

نویسندگان

  • Bengtsson
  • Heijl
چکیده

PURPOSE To study whether false-negative answers in computerized glaucoma perimetry indicate the patient's ability to perform perimetry or test result reliability. METHODS A retrospective evaluation was performed of visual field test results obtained with a perimetry program (Humphrey 30-2 Sita Standard; Humphrey Instruments, San Leandro, CA) in 70 consecutive patients with unilateral glaucomatous field loss. Frequencies of false-negative answers were compared between the two eyes of each patient and related to amount of visual field damage in the glaucomatous eyes using linear regression analysis. RESULTS Frequencies of false-negative answers were higher in eyes with field loss. The intrapatient intereye difference was 6.6% on average (P < 0.0001). In seven subjects with false-negative frequency of 5% or more in both eyes, the mean difference was 12.7% between eyes. The differences in false-negative answers depended significantly on the amount of field loss in the glaucomatous eyes (P = 0.0003). Larger differences were seen in patients with advanced field loss in the affected eye. CONCLUSIONS The increased frequencies of false-negative answers in eyes with field loss were strongly associated with field status. The higher false-negative frequencies in eyes with glaucomatous field loss compared with unaffected eyes may be explained by the increased variability in threshold values typically found in such eyes. False-negative answers in patients with glaucoma therefore represent eye rather than patient status.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Automated Perimetry Performance in Elderly Subjects after Listening To Mozart

PURPOSE To evaluate the performance of automated perimetry of elderly subjects naïve to AP after listening to a Mozart sonata. INTRODUCTION Automated perimetry (AP) is a psychophysical test used to assess visual fields in patients with neurological disorders and glaucoma. In a previous study, Fiorelli et al. showed that young subjects who listened to a Mozart sonata prior to undergoing AP per...

متن کامل

Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

PURPOSE To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression ...

متن کامل

Role of visual field reliability indices in ruling out glaucoma.

IMPORTANCE Standard automated perimetry is the current criterion standard for assessment of visual field (VF) loss in glaucoma. The 3 commonly used reliability indices to judge the quality of standard automated perimetry results are fixation losses (FLs) and false-positive (FP) and false-negative (FN) response rates. However, the influence of reliability indices, when within the manufacturer-re...

متن کامل

Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fo...

متن کامل

Modeling the sensitivity to variability relationship in perimetry

PURPOSE Studies in glaucoma patients show that standard automated perimetry results increase in variability as sensitivity decreases. However, the reasons for this change are unclear. This study presents the principle of Divergent Dysfunction as a possible explanation for this change in variability, and incorporates it into a model that can be used to simulate perimetry. METHODS A computer pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 41 8  شماره 

صفحات  -

تاریخ انتشار 2000