The effects of apparatus dead space on P(aCO2) in patients receiving lung-protective ventilation.
نویسندگان
چکیده
BACKGROUND Lung-protective ventilation using tidal volume (V(T)) of 4-6 mL/kg (predicted body weight) reduces mortality (compared with traditional V(T)) in patients with acute respiratory distress syndrome and acute lung injury. Standardized use of lower V(T) can result in respiratory acidosis and has raised new concerns about the appropriate configuration of the ventilator circuit, especially in regard to the dead space (V(D)) of the apparatus. We hypothesized that, with a patient receiving lung-protective ventilation, the removal of all apparatus dead space from the circuit would reduce P(aCO2) and allow a reduction in minute ventilation. METHODS All the studied patients met the American-European consensus-conference criteria for acute respiratory distress syndrome/acute lung injury, were receiving a lung-protective ventilation strategy, were > 18 years of age, and were hemodynamically stable. We prospectively tested 3 different ventilator-circuit configurations, in random sequence, for 15 min each: (1) standard hygroscopic heat-and-moisture exchanger (HME) with 15-cm flexible tubing, (2) 15-cm flexible tubing only, (3) no HME or flexible tubing. V(T), respiratory rate, positive end-expiratory pressure, and fraction of inspired oxygen were maintained constant throughout the study, and exhaled CO2 was measured continuously. Physiologic dead space (V(D)/V(T)) was calculated using the Enghoff modification of the Bohr equation. RESULTS Seven patients were studied. Removal of the HME from the circuit significantly decreased V(D)/V(T) (by approximately 6%) and P(aCO2) (by approximately 5 mm Hg). Removal of both the HME and flexible tubing from the circuit reduced V(D)/V(T) by an additional 5%, and P(aCO2) by an additional 6 mm Hg. With both circuit-configuration changes, minute ventilation fell from a mean of 11.51 L/min to 10.35 L/min, and pH increased from 7.30 to 7.38. Carbon-dioxide production did not change significantly. CONCLUSION In patients receiving lower-V(T) ventilation, removing all the apparatus V(D) from the ventilator circuit reduces P(aCO2) and increases pH, at a lower minute ventilation. This information will help guide ventilator-circuit configuration for patients receiving lung-protective ventilation.
منابع مشابه
Algorithms to estimate PaCO2 and pH using noninvasive parameters for children with hypoxemic respiratory failure.
BACKGROUND Ventilator management for children with hypoxemic respiratory failure may benefit from ventilator protocols, which rely on blood gases. Accurate noninvasive estimates for pH or P(aCO2) could allow frequent ventilator changes to optimize lung-protective ventilation strategies. If these models are highly accurate, they can facilitate the development of closed-loop ventilator systems. W...
متن کاملVentilation with increased apparatus dead space vs positive end-expiratory pressure: effects on gas exchange and circulation during anesthesia in a randomized clinical study.
Atelectasis formation can be reduced by positive end-expiratory pressure (PEEP), but resulting increases in intrathoracic pressure could affect circulation. We have earlier demonstrated that increased tidal volumes with larger apparatus dead space improves oxygenation and sevoflurane uptake. In the present study, we hypothesize that isocapnic ventilation with increased tidal volumes increases o...
متن کاملThe Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)
Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...
متن کاملModified inspiratory flow pattern - a tool for lung protective ventilation
Introduction Lung protective ventilation, LPV, is recommended for ever wider patient populations, even those without primary lung disease. Low tidal volume ventilation is a first-hand remedy for LPV that is facilitated by dead space reduction. Inspiratory flow pattern affects gas exchange. In ARDS patients, it was recently shown that a long period during which inspired tidal gas is in contact w...
متن کاملThe effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
BACKGROUND Passive humidifiers have gained acceptance in the intensive care unit because of their low cost, simple operation, and elimination of condensate from the breathing circuit. However, the additional dead space of these devices may adversely affect respiratory function in certain patients. This study evaluates the effects of passive humidifier dead space on respiratory function. METHO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory care
دوره 51 10 شماره
صفحات -
تاریخ انتشار 2006