Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies

نویسندگان

  • Michael Mahler
  • Jennifer T Ngo
  • Johannes Schulte-Pelkum
  • Tanja Luettich
  • Marvin J Fritzler
چکیده

INTRODUCTION Autoantibodies to the ribosomal P proteins represent a highly specific marker for the diagnosis of systemic lupus erythematosus, where they have been associated with certain clinical manifestations. Historically, autoantibodies against ribosomal P proteins have been detected by indirect immunofluorescence, immunodiffusion, immunoblot, and other immunoassays. More recently, enzyme-linked immunosorbent assays and line and addressable laser bead immunoassays have become more widely used. The primary goal of this study was to determine the sensitivity of indirect immunofluorescence using conventional HEp-2 substrates in the detection of sera with ribosomal P antibodies as detected by other immunoassays. METHODS Anti-ribosomal P-positive sera (n = 345) as detected by an addressable laser bead immunoassay were collected between 2003 and 2007 and analysed by indirect immunofluorescence. Furthermore, 51 anti-ribosomal P-positive samples from an unselected systemic lupus erythematosus cohort (n = 100) and the Centers for Disease Control and Prevention (CDC) anti-nuclear antibody (ANA) reference sera were tested for anti-ribosomal P reactivity. RESULTS In the cohort of 345 anti-ribosomal P-positive samples identified by addressable laser bead immunoassay, a low sensitivity (<30%) of indirect immunofluorescence on HEp-2 cell substrates was observed. Although the degree of sensitivity varied among different manufacturers, all immunofluorescence substrates exhibited limited sensitivity and false-negative results were not restricted to samples with low anti-ribosomal P titers. Even the anti-ribosomal P reactivity of CDC ANA reference serum number 12 was not clearly predictable by indirect immunofluorescence. Comparison of five different methods for the detection of anti-ribosomal P found moderate qualitative agreements. CONCLUSIONS Based on our data, we conclude that indirect immunofluorescence on HEp-2 cells is not a reliable screening test for the prediction of ribosomal P antibodies. As this method is widely used as a first-line screening test for anti-nuclear and other autoantibodies, special considerations for the detection of ribosomal P antibodies are needed. As with many other autoantibodies, further effort is required for the standardisation of ribosomal P immunoassays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies

Reference 1. Mahler M, Ngo JT, Schulte-Pelkum J, Luettich T, Fritzler MJ: Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies. Arthritis Res Ther 2008, 10:R131. Correction Correction: Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies Michael Mahler1, Jennifer T Ngo2, Johannes Schult...

متن کامل

AIT test has no problem in the detection of anti-ribosomal P – authors' response

In a recent article, Jearn and Kim assessed the ability of indirect immunofluorescence on a novel human macrophage cell line (IT-1) in an autoimmune target (AIT) assay to predict the presence of anti-ribosomal P (anti-Rib-P) antibodies [1], based on a previously described cytoplasmic and/or nucleolar staining pattern [2]. Despite the clearance of the AIT test by the South Korea Food and Drug Ad...

متن کامل

Development of Indirect Immunofluorescence Technique for the Identification of MRC5 Working Seed Cell

Diploid and continuous cell lines are used to propagate viral vaccines. At Human Viral Vaccine Department of Razi Vaccine and Serum Research Institute, MRC5 diploid cell is used for the development of live attenuated measles, mumps, rubella, and three types of poliovirus vaccines.  Additionally, three continuous cell lines (i.e., RK13, HeLa, and Vero) are applied in quality control tests. Accor...

متن کامل

Comparison of Immunoblotting and ELISA for Detection of Anti-Ganglioside Antibodies in Children with Guillain-Barre Syndrome

Background: Anti-ganglioside antibody assays are widely used for diagnosis of autoimmune peripheral neuropathies. Objective: This study aimed to determine serum levels of anti-ganglioside antibodies in children with Guillain-Barre syndrome by immunoblotting technique and compare the results with those obtained by ELISA method. Method: In this investigation, 50 children with Guillain-Barre syndr...

متن کامل

Development and ELISA-based detection of anti-M2e IgY antibodies using an encoding plasmid for M2e-Hsp70 C-terminal gene

Background: The use of IgYs in a variety of methods in different areas of research, diagnostics, medical application and biotechnology should be considered widely. Objectives: Development of antibodies against extra cellular domain of influenza M2 (M2e) protein in egg yolk of laying hens. Methods: A Fusion construct harboring C-terminal of bovine heat shock protein 70 (Hsp70) and influenza M2e ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthritis Research & Therapy

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2008