Wear versus Thickness and Other Features of 5-Mrad Crosslinked UHMWPE Acetabular Liners

نویسندگان

  • Fu-Wen Shen
  • Zhen Lu
  • Harry A. McKellop
چکیده

BACKGROUND The low wear rates of crosslinked polyethylenes provide the potential to use larger diameters to resist dislocation. However, this requires the use of thinner liners in the acetabular component, with concern that higher contact stresses will increase wear, offsetting the benefits of the crosslinking. QUESTIONS/PURPOSES We asked the following questions: Is the wear of conventional and crosslinked polyethylene liners affected by ball diameter, rigidity of backing, and liner thickness? Are the stresses in the liner affected by thickness? METHODS Wear rates were measured in a hip simulator and stresses were calculated using finite element modeling. RESULTS Without crosslinking, the wear rate was 4% to 10% greater with a 36-mm diameter than a 28-mm diameter. With crosslinking, wear was 9% lower with a 36-mm diameter without metal backing and 4% greater with metal backing. Reducing the thickness from 6 mm to 3 mm increased the contact stress by 46%, but the wear rate decreased by 19%. CONCLUSIONS The reduction in wear with 5 Mrad of crosslinking was not offset by increasing the diameter from 28 mm to 36 mm or by using a liner as thin as 3 mm. CLINICAL RELEVANCE The results indicate, for a properly positioned 5-Mrad crosslinked acetabular component and within the range of dimensions evaluated, neither wear nor stresses in the polyethylene are limiting factors in the use of larger-diameter, thinner cups to resist dislocation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

‘severe’ Wear Challenge to 36 Mm Mechanically Enhanced Crosslinked Polyethylene Hip Cups

Introduction Recent studies have shown that sequential irradiation/annealing processes improves the wear performance and oxidation resistance of crosslinked polyethylene, while maintaining mechanical properties [1,2]. Although these early results showed great promise for mechanically enhanced XLPE, we still know little about the variables that can lead to high-wear, particularly surface roughne...

متن کامل

The comparison of the wear behavior of four different types of crosslinked acetabular components.

Introduction: Crosslinking of polyethylene has been known for decades to improve the abrasion resistance of the polymer for industrial applications. However, only three applications of this technology have been reported in use in total hip replacements in the orthopaedics literature by Grobbelaar et. al. [1], Oonishi et. al. [2], and Wroblewski et. al. [3]. Recently, the interest in highly cros...

متن کامل

Wear of Crosslinked Uhmwpe in a Hip Joint Simulator

Crosslinking has been extensively introduced to reduce the wear of UHMWPE. In this study the wear rates and wear surfaces of UHMWPE with different levels of crosslinking were compared in a hip joint simulator. The UHMWPE was either non-irradiated, gamma irradiated in air (2.5MRad), or highly crosslinked (7.5 and 10MRad). The intentionally crosslinked materials showed a significantly lower volum...

متن کامل

Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film.

Stress magnitude and distribution of both conventional polyethylene versus a crosslinked polyethylene in the liner of a total hip replacement (THR) were examined using finite element analysis and pressure sensitive film. Both types of polyethylene were assessed against head sizes of 22 and 28 mm with 5-mm thick polyethylene liners and head sizes of 28, 38, and 46 mm with 3-mm thick polyethylene...

متن کامل

Thin-Walled Cross-Linked Acetabular Liners Need Not Exhibit Reduced Locking Strength.

Use of larger diameter femoral heads has emerged as a promising strategy to reduce the risk of dislocation after total hip arthroplasty, but thinning the walls of cross-linked ultra-high-molecular-weight polyethylene (UHMWPE) acetabular liners to accommodate these larger heads may compromise the locking mechanism of the liner. The purpose of this study was to test the mechanical integrity of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 469  شماره 

صفحات  -

تاریخ انتشار 2011