Estimation of current density distribution under electrodes for external defibrillation

نویسندگان

  • Vessela Tz Krasteva
  • Sava P Papazov
چکیده

BACKGROUND Transthoracic defibrillation is the most common life-saving technique for the restoration of the heart rhythm of cardiac arrest victims. The procedure requires adequate application of large electrodes on the patient chest, to ensure low-resistance electrical contact. The current density distribution under the electrodes is non-uniform, leading to muscle contraction and pain, or risks of burning. The recent introduction of automatic external defibrillators and even wearable defibrillators, presents new demanding requirements for the structure of electrodes. METHOD AND RESULTS Using the pseudo-elliptic differential equation of Laplace type with appropriate boundary conditions and applying finite element method modeling, electrodes of various shapes and structure were studied. The non-uniformity of the current density distribution was shown to be moderately improved by adding a low resistivity layer between the metal and tissue and by a ring around the electrode perimeter. The inclusion of openings in long-term wearable electrodes additionally disturbs the current density profile. However, a number of small-size perforations may result in acceptable current density distribution. CONCLUSION The current density distribution non-uniformity of circular electrodes is about 30% less than that of square-shaped electrodes. The use of an interface layer of intermediate resistivity, comparable to that of the underlying tissues, and a high-resistivity perimeter ring, can further improve the distribution. The inclusion of skin aeration openings disturbs the current paths, but an appropriate selection of number and size provides a reasonable compromise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Princiles Study of the Electron Transport Properties of Buthane-dithiol Nano-Molecular Wire

We report a first-principles study of electrical transport in a single molecular conductor consisting of a buthane-dithiol sandwiched between two Au (100) electrodes. We show that the current was increased by increasing of the external voltage biases. The projected density of states (PDOS) and transmission coefficients (T(E)) under various external voltage biases are analyzed, and it suggests t...

متن کامل

Biphasic waveform external defibrillation thresholds for spontaneous ventricular fibrillation secondary to acute ischemia.

OBJECTIVES The goal of this study was to determine if the defibrillation threshold (DFT) after spontaneous ventricular fibrillation (VF) secondary to acute ischemia differs from the DFT for electrically induced VF in the absence of ischemia in anesthetized, closed-chest dogs and pigs. BACKGROUND The efficacy of external defibrillators has been tested mainly in animals and humans using E-VF, y...

متن کامل

Determinants of Intracardiac Current in Defibrillation

Defibrillation success depends upon the amount and distribution of intracardiac current (IC), because only a portion of total current flow between the paddles actually traverses the heart. We evaluated two determinants of IC: paddle size and shock energy. Studies were performed in 11 anesthetized dogs using a damped-sine wave form defibrillator. Intramyocardial electrode pairs were implanted su...

متن کامل

External cardiac pacing using low impedance electrodes suitable for defibrillation: a comparative blinded study.

OBJECTIVES The objective of this study was to determine whether the threshold for successful cardiac pacing is affected by electrode impedance and whether this procedure can be successfully carried out through low impedance electrodes that are also suitable for defibrillation. BACKGROUND Reintroduced in the early 1980s, external cardiac pacing utilizes large externally placed electrodes with ...

متن کامل

Atrioventricular Nodal Reentrant Paroxysmal Tachycardia

amount of myocardium. Am J Cardiol 36: 37, 1975 5. Ewy GA: Defibrillation paddle electrodes. Proceedings of the Cardiac Defibrillation Conference, Purdue University, West Lafayette, Indiana, 1975, p 39 6. Ewy GA: Effectiveness of direct current defibrillation. Role of paddle electrode size. I1. Am Heart J 93: 674, 1977 7. Rush S, Lepeschkin E, Gregaritsch A: Current distribution from defibrilla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2002