Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry.
نویسندگان
چکیده
AIMS The development of imaging and measurement techniques has brought the prospect of greater objectivity in the measurement of optic disc features, and therefore better agreement between observers. The purpose of this study was to quantify and compare the variation between observers using two measurement devices. METHODS Optic disc photographs and images from the Heidelberg retina tomograph (HRT) of 30 eyes of 30 subjects were presented to six observers for analysis, and to one observer on five separate occasions. Agreement between observers was studied by comparing the analysis of each observer with the median result of the other five, and expressed as the mean difference and standard deviation of differences between the observer and the median. Inter- and intraobserver variation was calculated as a coefficient of variation (mean SD/mean x 100). RESULTS For planimetry, agreement between observers was dependent on observer experience, for the HRT it was independent. Agreement between observers (SD of differences as a percentage of the median) for optic disc area was 4.0% to 7.2% (planimetry) and 3.3% to 6.0% (HRT), for neuroretinal rim area it was 10.8% to 21.0% (planimetry) and 5.2% to 9.6% (HRT). The mean interobserver coefficient of variation for optic disc area was 8.1% (planimetry) and 4.4% (HRT), for neuroretinal rim area it was 16.3% (planimetry) and 8.1% (HRT), and (HRT only) for rim volume was 16.3%, and reference height 9.1%. HRT variability was greater for the software version 1.11 reference plane than for version 1.10. The intraobserver coefficient of variation for optic disc area was 1.5% (planimetry) and 2.4% (HRT), for neuroretinal rim area it was 4.0% (planimetry) and 4.5% (HRT). CONCLUSIONS Variation between observers is greatly reduced by the HRT when compared with planimetry. However, levels of variation, which may be clinically significant, remain for variables that depend on the subjective drawing of the disc margin.
منابع مشابه
CLINICAL SCIENCE Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph
Aims: To assess the intraobserver agreement, interobserver agreement, and the agreement between a digital stereo optic disc camera (Discam) and Heidelberg retina tomograph (HRT) in measuring area cup-disc ratio (ACDR) and radial cup-disc ratio (RCDR) by two observers. Methods: The optic discs of 78 eyes of 39 people (17 cases of primary open angle glaucoma, eight normal tension glaucoma, two oc...
متن کاملAgreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph.
AIMS To assess the intraobserver agreement, interobserver agreement, and the agreement between a digital stereo optic disc camera (Discam) and Heidelberg retina tomograph (HRT) in measuring area cup-disc ratio (ACDR) and radial cup-disc ratio (RCDR) by two observers. METHODS The optic discs of 78 eyes of 39 people (17 cases of primary open angle glaucoma, eight normal tension glaucoma, two oc...
متن کاملAutomatic Optic Disc Center and Boundary Detection in Color Fundus Images
Accurately detection of retinal landmarks, like optic disc, is an important step in the computer aided diagnosis frameworks. This paper presents an efficient method for automatic detection of the optic disc’s center and estimating its boundary. The center and initial diameter of optic disc are estimated by employing an ANN classifier. The ANN classifier employs visual features of vessels and th...
متن کاملMorphological Exudate Detection in Retinal Images using PCA-based Optic Disc Removal
Diabetic retinopathy lesion detection such as exudate in fundus image of retina can lead to early diagnosis of the disease. Retinal image includes dark areas such as main blood vessels and retinal tissue and also bright areas such as optic disk, optical fibers and lesions e.g. exudate. In this paper, a multistage algorithm for the detection of exudate in foreground is proposed. The algorithm se...
متن کاملIntraobserver and interobserver reproducibility in the evaluation of optic disc stereometric parameters by Heidelberg Retina Tomograph.
PURPOSE To assess intraobserver and interobserver reproducibility of the measurement of stereometric parameters of the optic disc by means of the Heidelberg Retina Tomograph I (HRT). STUDY DESIGN Observational study, with interobserver variability. PARTICIPANTS Fifty-five volunteers (healthy subjects and patients with glaucoma). METHODS HRT examination of the optic disc was repeated on 3 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 83 6 شماره
صفحات -
تاریخ انتشار 1999