Determination of properties of individual liposomes by capillary electrophoresis with postocolumn laser-induced fluorescence detection.
نویسندگان
چکیده
Individual liposome measurements by capillary electrophoresis with postcolumn laser-induced fluorescence detection facilitated the determination of liposome property distributions, two-dimensional plots, and an improved characterization of a liposomal preparation. This advancement in liposome analysis was feasible by using a high-sensitivity postcolumn laser-induced fluorescence detector wired for millisecond response. For each individual liposome containing fluorescein, peak height and migration time were determined. From these measurements the individual entrapped volumes and electrophoretic mobilities were determined. Distribution analysis of these properties facilitated comparison of various liposome dilutions and indicated that the method is reproducible and unaffected by the density of liposomes (10(7)-10(9) liposomes/mL) in the suspension. Furthermore, liposomes showed entrapped volumes that vary from 0.3 to 13 fL with apparent radius varying from 370 nm to 1.8 microns. Two-dimensional plots of reduced mobility versus kappa R (Debye parameter x liposome radius) revealed that the liposomes resuspended from a dried film of phospholipids are heterogeneous in regard to the surface charge density of individual liposomes. The described method has the potential of becoming a new tool for characterization of commercial liposomal preparations and theoretical studies.
منابع مشابه
High-sensitivity laser-induced fluorescence detection for capillary electrophoresis.
Capillary electrophoresis provides very high efficiency separations of biological molecules. Laser-induced fluorescence produces very high sensitivity detection. The combination of the two techniques results in an analytical tool with unprecedented properties: separations with more than a million theoretical plates and detection limits of a few hundred analyte molecules. This paper considers th...
متن کاملAutomated analysis of individual particles using a commercial capillary electrophoresis system.
Capillary electrophoretic analysis of individual submicrometer size particles has been previously done using custom-built instruments. Despite that these instruments provide an excellent signal-to-noise ratio for individual particle detection, they are not capable of performing automated analyses of particles. Here we report the use of a commercial Beckman P/ACE MDQ capillary electrophoresis (C...
متن کاملDetermination of electrophoretic mobility distributions through the analysis of individual mitochondrial events by capillary electrophoresis with laser-induced fluorescence detection.
Here we report on the analysis of mitochondrial preparations by capillary electrophoresis with postcolumn laser-induced fluorescence detection. Individual mitochondria are detected by fluorescent labeling with the mitochondrion-selective probe, 10-nonyl acridine orange. Interactions between the organelles and the capillary walls are controlled by derivatization of the capillaries with poly(acry...
متن کاملDevelopment of near-infrared fluorophoric labels for the determination of fatty acids separated by capillary electrophoresis with diode laser induced fluorescence detection†
Synthesis and characterization of a polymethine cyanine near-infrared (NIR) fluorophoric label for the derivatization and determination of fatty acids separated by capillary electrophoresis are described. The label contains an aromatic amine functionality, which is used to form a covalent linkage with the analyte. Various linking chemistries are explored, including direct amine–acid condensatio...
متن کاملPotential determination of aminated pesticides and metabolites by cyclodextrin capillary electrophoresis-laser-induced fluorescence using FITC as labelling.
We describe a detailed study on the possibility of analyzing aminated pesticides and metabolites using pre-column derivatization with fluorescein isothiocyanate (FITC) and their subsequent separation and detection by cyclodextrin capillary electrophoresis-laser-induced fluorescence (CE-LIF) detection. Different variables affecting the derivatization reaction (pH, FITC concentration, reaction ti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 73 8 شماره
صفحات -
تاریخ انتشار 2001