Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique

نویسندگان

  • Andrew D Shaw
  • Zheng Li
  • Zach Thomas
  • Craig W Stevens
چکیده

INTRODUCTION AND METHODS Dynamic fluorescence quenching is a technique that may overcome some of the limitations associated with measurement of tissue partial oxygen tension (PO2). We compared this technique with a polarographic Eppendorf needle electrode method using a saline tonometer in which the PO2 could be controlled. We also tested the fluorescence quenching system in a rodent model of skeletal muscle ischemiahypoxia. RESULTS Both systems measured PO2 accurately in the tonometer, and there was excellent correlation between them (r(2) = 0.99). The polarographic system exhibited proportional bias that was not evident with the fluorescence method. In vivo, the fluorescence quenching technique provided a readily recordable signal that varied as expected. DISCUSSION Measurement of tissue PO2 using fluorescence quenching is at least as accurate as measurement using the Eppendorf needle electrode in vitro, and may prove useful in vivo for assessment of tissue oxygenation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polarographic Oxygen Electrode

A method has been developed for the continuous monitoring of oxygen tension in solutions and gases. The oxygen is reduced at a platinum surface which is covered with a plastic membrane. The silver-silver oxide reference electrode is also included under the membrane. Drift is less than 10 per cent for a period of days, and temperature compcnsation is possible. A number of uses to which it has be...

متن کامل

Measurement of tumor oxygenation: a comparison between polarographic needle electrodes and a time-resolved luminescence-based optical sensor.

A novel oxygen sensor which does not rely on electrochemical reduction has been used to measure the oxygenation of the murine sarcoma F in a comparative study with an existing polarographic electrode that is available commercially. The prototype luminescence sensor yielded an oxygen distribution comparable with readings made using a pO2 histograph. The percentage of regions detected that had a ...

متن کامل

Skin Oxygen Tension During Administration of Epinephrine and Norepinephrine to Normal Man ‡

Epinephrine and norepinephrine are biologically active substances which are normally reflexly released in response to a number of stressful situations including hypoxia,7'' " hypercarbia,'7"' hemorrhage, ",7" and general anesthesia.'""" In the process of evaluating the effects of such stressful situations on the amount of oxygen in tissue and available for normal cellular respiration and metabo...

متن کامل

In vivo oxygen uptake into the human cornea.

PURPOSE We provide a new procedure to quantify in situ corneal oxygen uptake using the micropolarographic Clark electrode. METHODS Traditionally, upon placing a membrane-covered Clark microelectrode onto a human cornea, the resulting polarographic signal is interpreted as the oxygen partial pressure at the anterior corneal surface. However, the Clark electrode operates at a limiting current. ...

متن کامل

The dynamic response of optical oxygen sensors and voltammetric electrodes to temporal changes in dissolved oxygen concentrations

Accurately measuring dissolved oxygen concentrations in fresh and salt water environments has long been an interdisciplinary priority. Many methodologies exist, including two very promising new ones, optical fluorescence quenching optrodes (or optodes) and solid-state voltammetric electrodes. In this study we compare the responsiveness of these two techniques to dynamic changes in dissolved oxy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2002