A histological and histomorphometrical evaluation of the application of screw-designed calciumphosphate (Ca-P)-coated implants in the cancellous maxillary bone of the goat.

نویسندگان

  • H Caulier
  • J P van der Waerden
  • J G Wolke
  • W Kalk
  • I Naert
  • J A Jansen
چکیده

Various studies already have shown that the occurrence of oral implant failure is higher in the maxilla than in the mandible. To learn whether Ca-P coatings can improve the success rate of oral implants in the maxilla, three different plasma-sprayed, Ca-P-coated, self-tapping Brånemark implants were inserted in the trabecular bone of the maxilla. Before the insertion of the implants, the two first upper premolars of 16 goats were bilaterally extracted. Four months later, each animal received four types of implants: three different Ca-P-coated types and one uncoated. After an endosseous period of 6 months, the implants were provided with permucosal abutments. Four months later the animals were killed. At the end of the experiment, it appeared that 10 of the 16 installed noncoated implants had failed while of the 48 Ca-P-coated implants, only 6 had failed. All successful implants were retrieved and prepared for histomorphometrical evaluation of the bone and gingiva response. The Ca-P-coated implants showed a significantly greater percentage of bone in contact with the implant surface compared with the uncoated implants. The length of the epithelium was not significantly different for the coated compared to the uncoated implants, but the connective tissue was significantly thicker for the noncoated implants than for the Ca-P-coated implants. Also, measurements revealed that all coatings showed reduction in thickness. On the basis of these findings, we concluded that the application of Ca-P coatings (1) improves the bone-implant reaction, although all coatings reduced in thickness, and (2) is of benefit during the healing period in less mineralized trabecular bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical and histologic evaluation of Ca-P plasma-spray and magnetron sputter-coated implants in trabecular bone of the goat.

To aim of this study was to investigate the bone response to calcium phosphate (Ca-P) plasma-spray and radiofrequency magnetron sputter-coated implants with comparable roughness. Therefore, tapered conical screw designed implants were installed in the trabecular bone of the femurs of nine goats. They were provided with two types of coatings, a plasma-spray dual coating of fluorapatite and hydro...

متن کامل

Effect of calcium phosphate (Ca-P) coatings on trabecular bone response: a histological study.

The trabecular bone response to noncoated and fluorapatite (FA), hydroxyapatite (HA), and hydroxyapatite heat-treated (HAHT) plasma-sprayed coated implants was investigated in a goat animal model. Forty-eight cylindrical implants were inserted into the trabecular bone of the lateral and medial femoral condyles of twelve goats according to a split plot design. After an implantation period of twe...

متن کامل

The effect of platelet-rich plasma on the bone healing around calcium phosphate-coated and non-coated oral implants in trabecular bone.

The effect of local application of autologous platelet-rich plasma (PRP) on bone healing in combination with the use of titanium implants with 2 different surface configurations was investigated. PRP fractions were obtained from venous blood sample of 6 goats and applied via gel preparation and subsequent installation in the implant site or via dipping of the implant in PRP liquid before insert...

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

Evaluation the Accuracy of Lineartomography in Determining the Quantity of Maxillary Bone

Background & Aims: The accuracy of dental implants has increased in recent years. An accurate radiography from the region is needed for precise treatment planning in implants and for determining prognosis of treatment. Because this technique can demonstrate the buccolingual aspect, and due to its lower radiation dose, lower cost, and availability, in comparison with computed tomography, lineart...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 1997