Cryosurgical left-sided maze procedure in patients with valvular heart disease: medium-term results.

نویسندگان

  • Yoshimasa Sakamoto
  • Hiromitsu Takakura
  • Katsuhisa Onoguchi
  • Takashi Hachiya
  • Tatsuumi Sasaki
  • Michio Yoshitake
  • Kazuhiro Hashimoto
چکیده

PURPOSE We evaluated medium-term results of the left-sided maze procedure using cryoablation in patients with valvular heart disease. METHODS We retrospectively evaluated 111 patients with valvular heart disease who underwent the cryosurgical left-sided maze procedure. The mean follow-up period was 36.8 ± 24.9 months, and the mean duration of atrial fibrillation was 5.6 ± 6.0 years. The primary surgical procedure was mitral valve replacement in 42 patients, mitral valve plasty in 28, aortic valve replacement in 25, and combined aortic and mitral replacement or plasty in 16. RESULTS The 7-year actuarial survival rate was 82.9 ± 11.4% for patients in sinus rhythm and 87.0 ± 7.0% for patients with atrial fibrillation, showing no difference between the two groups (p = 0.236). At final follow-up, 86 out of 111 patients (77.5%) remained free from atrial fibrillation. Sinus rhythm was maintained in 26 of 42 patients (61.9%) in the mitral valve replacement group, 26 of 28 patients (92.9%) in the mitral valve plasty group, 15 of 17 patients (88.2%) in the aortic valve replacement group, and 18 of 24 patients (75.0%) in the combined aortic and mitral replacement or plasty group. The overall actuarial rate of freedom from atrial fibrillation at 5 years after surgery was 70.4 ± 6.0%. CONCLUSION The cryosurgical left-sided maze procedure is a safe, simple, and excellent operation for medically refractory atrial fibrillation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The modern surgical management of atrial fibrillation.

Atrial fibrillation is the most common arrhythmia disorder. Its incidence is especially high among patients with valvular heart disease. Patients with atrial fibrillation are at a six-fold increased risk of stroke and a two-fold increased risk of mortality. Medical management for rhythm control of patients with atrial fibrillation is suboptimal and no better than simple rate management. However...

متن کامل

DOPPLER ECHOCARDIOGRAPHY IN SUBCLINICAL RHEUMATIC VALVULAR REGURGITATION: ALONGTERM STUDY

Doppler echocardiography (DE) is known to be a valuable tool for detecting subclinical forms of valvular regurgitation (VRJ in theacutephase of rheumatic fever (RF). Previous studies have mostly dealt with the acute phase problem with only short-term follow-up. In this study, 24 children between 4-15 years of age (mean age II.X±2.7 years) with RF without clinically diagnosed carditis (most ...

متن کامل

Impact of Right-Sided-Catheter-Based Valve Implantation on Decision-Making in Congenital Heart Disease

There is a growing appreciation for the adverse long-term impact of right-sided valvular dysfunction in patients with congenital heart disease. Although right-sided valvular stenosis and/or regurgitation is often better tolerated than left-sided valvular dysfunction in the short and intermediate term, the long-term consequences are numerous and include, but are not limited to, arrhythmias, hear...

متن کامل

Long-term outcomes of mechanical valve replacement in patients with atrial fibrillation: impact of the maze procedure.

BACKGROUND The long-term benefits of the maze procedure in patients with chronic atrial fibrillation undergoing mechanical valve replacement who already require lifelong anticoagulation remain unclear. METHODS AND RESULTS We evaluated adverse outcomes (death; thromboembolic events; composite of death, heart failure, or valve-related complications) in 569 patients with atrial fibrillation-asso...

متن کامل

Surgical Outcomes of Cox-maze IV Procedure Using Bipolar Irrigated Radiofrequency Ablation and Cryothermy in Valvular Heart Disease

BACKGROUND We evaluated the efficacy of Cox-maze IV procedure using bipolar irrigated radiofrequency ablation and cryothermy in chronic atrial fibrillation associated with valvular heart disease. MATERIAL AND METHODS From November 2005 to June 2009, ninety four patients have undergone valvular heart surgery with Cox-maze IV procedure. Preoperative duration of atrial fibrillation was 7.6±6.5 y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2011