Acrylic toric intraocular lens implantation: a single center experience concerning clinical outcomes and postoperative rotation
نویسندگان
چکیده
PURPOSE To present clinical results of toric intraocular lens (IOL) implantation for preexisting astigmatism correction and determine the time of any postoperative rotation. PATIENTS AND METHODS Twenty-nine eyes of 19 patients underwent uncomplicated phacoemulsification and were implanted with an Acrysof ((c)) toric IOL. Uncorrected visual acuity, residual astigmatism, and postoperative rotation of the IOL were estimated one and six months after the operation. RESULTS Uncorrected visual acuity was >/=0.5 in 26 of 29 eyes (89.7%) and >/=0.8 in 19 of 29 patients (65.5%). The mean toric IOL axis rotation was 2.2 +/- 1.5 degrees (range 0.6-7.8 degrees ) one month postoperation and 2.7 +/- 1.5 degrees (range 0.9-8.4 degrees ) six months postoperation. CONCLUSION Implantation of one-piece hydrophobic acrylic toric IOLs appears to have acceptable stability, which encourages visual outcome and emerges as an attractive alternative for correction of refractive astigmatism.
منابع مشابه
Stability of a three-piece silicone intraocular lens implanted in the capsular bag
odern cataract surgery aims not only to remove lens opacities but also to achieve correction of any refractive error. In addition to restoration of uncorrected visual acuity, correction of preexisting astigmatism is also important, and treatment options for this purpose include corneal limbal relaxing incisions, excimer laser photoablation and toric intraocular lens (IOL) implantation. Shimizu ...
متن کاملClinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL) during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1 ± 11.4 years) with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with impl...
متن کاملResults of cataract surgery with Z-flex hydrophilic acrylic toric IOL.
PURPOSE To report the outcome of cataract surgery with implantation of the Z-flex 690TA hydrophilic acrylic toric intraocular lens (IOL). METHODS We enrolled consecutive patients who had 1.75 D or more of preexisting corneal astigmatism. Patients had cataract extraction surgery with implantation of a Z-flex 690TA toric IOL (Medicontur, Hungary). Refractive outcomes, keratometry, correction r...
متن کاملResults of the AcrySof Toric intraocular lenses implantation
BACKGROUND The expectations of post-removal cataract surgery patients are extremely high, and best vision acuity is expected. The best refractive results are influenced by two factors - cataract surgical removal and the corneal astigmatism correction. Currently, the two most often applied corneal astigmatism removal methods are laser surgery and toric intraocular lens implantation, with the lat...
متن کاملHigh-cylinder toric intraocular lens implantation versus combined surgery of low-cylinder intraocular lens implantation and limbal relaxing incision for high-astigmatism eyes
Clinical outcomes were compared between high-cylinder toric intraocular lens (IOL) implantation and the combined surgery of low-cylinder toric IOL implantation and limbal relaxing incision (LRI) for correcting preexisting high-amplitude corneal astigmatism. Fifty-seven eyes with preexisting corneal astigmatism of 2.5 diopter (D) or greater were divided into the following two groups: (1) eyes th...
متن کامل