Ultrasound for bubble detection

نویسندگان

  • Costantino Balestra
  • Robert van Hulst
چکیده

Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. The use of portable 2D echocardiography and ‘frame-based’ bubble counting as a tool to evaluate diving decompression stress. Diving and Hyperbaric Medicine. 2014 March;44(1):5-13.) Introduction: ‘Decompression stress’ is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profiles. We propose and validate a new ‘frame-based’ VGE-counting method which offers a continuous scale of measurement. Methods: Nine ‘raters’ of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new ‘frame-based’ counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were randomly repeated. A Wilcoxon Spearman rho calculation was used to assess test-retest reliability of each rater for the repeated still frames. For the video images, weighted kappa statistics, with linear and quadratic weightings, were calculated to measure agreement between raters for the Eftedal and Brubakk method. Bland-Altman plots and intra-class correlation coefficients were used to measure agreement between raters for the frame-based counting method. Results: Frame-based counting showed a better inter-rater agreement than the Eftedal and Brubakk grading, even with relatively inexperienced assessors, and has good intraand inter-rater reliability. Conclusion: Frame-based bubble counting could be used to evaluate post-dive decompression stress, and offers possibilities for computer-automated algorithms to allow near-real-time counting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Bubble Surface Charge on Phonophoresis

It is over several decades that ultrasound is used to enhance the transdermal drug delivery (phonphoresis). The mechanism of the enhancement is not fully understood and the ability of ultrasound on the enhancement for some drugs is unclear. The effect of continuous wave 870 KHz ultrasound at intensity of 1 W/cm 2 for 15 minutes on transdermal absorption of piroxicam from solution and gel formu...

متن کامل

Quantitative detection of bubble dynamics by Doppler ultrasound

Bubble cavitation is one of the major mechanisms for ultrasound-induced bioeffects. Characterising the bubble dynamics, expansion and collapse, is of importance in understanding the cavitation phenomenon and estimating the consequent outcome. In this study, Doppler ultrasound method was firstly used to measure the bubble wall velocity. Bubbles were generated in water using a beam of high-intens...

متن کامل

Modeling and investigating the effect of ultrasound waves pressure on the microbubble oscillation dynamics in microvessels containing an incompressible fluid (Research Article)

Understanding the dynamics of microbubble oscillation in an elastic microvessel is important for the safe and effective applications of ultrasound contrast agents in imaging and therapy. Numerical simulations based on 2D finite element model are performed to investigate the effect of acoustic parameters such as pressure and frequency on the dynamic interaction of the fluid-blood-vessel system. ...

متن کامل

Session 1pBB: Biomedical Ultrasound/Bioresponse to Vibration 1pBB9. Cooperative radiation and losses in bubble clusters

In existing models for single bubble dynamics it is necessary to account for radiation damping, a consequence of fluid compressibility. A similar correction is necessary when modeling systems of coupled bubbles. The coupling alters the collective dynamics and therefore the acoustic power radiated. In the linear approximation and for compact clusters in which the bubbles pulsate in phase, the ra...

متن کامل

Antenatally detected cystic biliary atresia: differential diagnoses of a double bubble

The 'double bubble' sign on antenatal ultrasound is often associated with duodenal atresia although there are numerous causes. We present a case of cystic biliary atresia presenting with a "double bubble" at 36-weeks gestation. Postnatal ultrasound and MRCP confirmed a cystic lesion at the porta hepatis, mandating early laparotomy and a successful Kasai portoenterostomy. Although diagnosis of s...

متن کامل

Blood Brain Barrier Disruption by Focused Ultrasound and Microbubbles: A Numerical Study on Mechanical Effects

Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014