In the past, Battery Energy Storage System (BESS) is used for primary frequency regulation. As developments in batteries progress, advancement in applications of BESS including the implementation in high power penetration is expected. Load shedding is one of frequency control methods during stand-alone operation, and the performance of frequency control improves in combination with BESS. However, without optimal size of BESS, it can cause the oscillations to the system. Thus, this article proposes the feasibility of using optimal BESS with load shedding scheme when the microgrid is disconnected from a main source. In this paper, the analytic algorithm-based DPL (DIgSILENT Programming Language) script is developed and presented to determine the optimal size of BESS with load shedding scheme. Results show that the optimal size of BESS-based analytic algorithm with load shedding scheme can achieve higher performance of frequency control compared to the BESS without optimal size. The optimal sizing method of BESS with load shedding scheme is achieved by using a tool for analysis of industrial, utility and commercial electrical power system called DPL script.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of Optimal Load Balancing Strategy for Hybrid Energy Management System in DC/AC Microgrid with PV and Battery Storage

The proposed paper presents the DC/AC microgrid modeling using the Energy storage units and photovoltaic (PV) panels. The modal consists of a two stage power conversion. The power is supplied to the both DC and AC loads by this PV solar panels. The suitable way to explore the PV generation model is by using manufacturer datasheet. A bidirectional converter is connected to the battery storage sy...

متن کامل

Optimal Economic Operation and Battery Sizing for Microgrid Energy Management Systems Considering Demand Response

Microgrids (MGs) contain a diverse mix of energy resources to provide safe and secure power to the consumers. Batteries are utilized in MGs for further energy security assurance as well as cost minimization. In this paper, an efficient approach is introduced for simultaneous energy management and optimal battery sizing to accomplish economic MG operation. Also, demand response programs are empl...

متن کامل

Optimal Sizing of Energy Storage System in A Renewable-Based Microgrid Under Flexible Demand Side Management Considering Reliability and Uncertainties

Utilization of energy storage system (ESS) in microgrids has turned to be necessary in recent years and now with the improvement of storage technologies, system operators are looking for an exact modeling and calculation for optimal sizing of ESS. In the proposed paper, optimal size of ESS is determined in a microgrid considering demand response program (DRP) and reliability criterion. Both lar...

متن کامل

System Stability-Constrainted Optimal Protection Coordination in the Microgrid Including Renewable Energy Sources and Energy Storage

In this paper, the system stability-constrianted optimal protection coordination (SSCOPC) as stochastic problem in the microgrid with grid-connected and islanded operation modes, including renewable energy sources (RESs) and energy storage systems (ESSs), is presented. This problem to optimal regulation of the dual setting overcurrent relays (DSORs) and selecting the reactance size of fault cur...

متن کامل

Using Reinforcement Learning to Make Smart Energy Storage Source in Microgrid

The use of renewable energy in power generation and sudden changes in load and fault in power transmission lines  may cause a voltage drop in the system and challenge the reliability of the system. One way to compensate the changing nature of renewable energies in the short term without the need to disconnect loads or turn on other plants, is the use of renewable energy storage. The use of ener...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014