Fatigue strength of common tibial intramedullary nail distal locking screws

نویسندگان

  • Lanny V Griffin
  • Robert M Harris
  • Joseph J Zubak
چکیده

BACKGROUND Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8-10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative and qualitative measures of the relative performance of these screws. METHODS Fatigue tests were conducted to simulate a comminuted fracture that was treated by IM nailing assuming that all load was carried by the screws. Each screw type was tested ten times in a single screw configuration. One screw type was tested an additional ten times in a two-screw parallel configuration. Fatigue tests were performed using a servohydraulic materials testing system and custom fixturing that simulated screws placed in the distal region of an appropriately sized tibial IM nail. Fatigue loads were estimated based on a seventy-five kilogram individual at full weight bearing. The test duration was one million cycles (roughly one year), or screw fracture, whichever occurred first. Failure analysis of a representative sample of titanium alloy and stainless steel screws included scanning electron microscopy (SEM) and quantitative metallography. RESULTS The average fatigue life of a single screw with a diameter of 4.0 mm was 1200 cycles, which would correspond roughly to half a day of full weight bearing. Single screws with a diameter of 4.5 mm or larger have approximately a 50 percent probability of withstanding a week of weight bearing, whereas a single 5.0 mm diameter screw has greater than 90 percent probability of withstanding more than a week of weight bearing. If two small diameter screws are used, our tests showed that the probability of withstanding a week of weight bearing increases from zero to about 20 percent, which is similar to having a single 4.5 mm diameter screw providing fixation. CONCLUSION Our results show that selecting the system that uses the largest distal locking screws would offer the best fatigue resistance for an unstable fracture pattern subjected to full weight bearing. Furthermore, using multiple screws will substantially reduce the risk of premature hardware failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of posterior tibial nail malpositioning on iatrogenic injuries by distal medio-lateral interlocking screws. A cadaveric study on plastinated specimens.

In intramedullary tibial nailing, multi-planar locking makes stabilization of proximal and distal metaphyseal fractures possible. A known complication in intramedullary nailing of the tibia is iatrogenic injury to neuro-vascular structures caused by the insertion of locking screws. As shown in previous studies, the distal positioning of the nail is important, as it determines the course of the ...

متن کامل

Intramedullary fixation of proximal tibial fractures

is challenging owing to the relatively high chance of displacement during nail insertion. The stability of the proximal fixation is inferior because of the wider diameter of the intramedullary canal in the metaphysis. This has led to the use of Poller screws for additional blocking during intramedullary fixation of proximal or distal tibial fractures.1 The effects of Poller screw is two-fold. F...

متن کامل

The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures

Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...

متن کامل

The biomechanics of varied proximal locking screw configurations in a synthetic model of proximal third tibial fracture fixation.

OBJECTIVE To determine if 1) angularly stable devices created by compressing ("locking") proximal locking screws to intramedullary nails using end caps or compression screws or 2) increasing the number of proximal screws from two to three increases the stiffness of intramedullary constructs that stabilize proximal third tibia fractures in a nonosteopenic bone model. METHODS Four proximal lock...

متن کامل

Anterior Tibial Artery Impingement by a Distal Interlocking Screw: A Case Report

A case is presented of a twenty-eight-year-old male with bilateral closed tibial fractures presenting with no right posterior tibial pulse, who was treated with bilateral reamed intramedullary nails. A post-operative arteriogram, to assess injury to the posterior tibial artery due to the initial insult, revealed impingement of the right anterior tibial artery by the most distal screw of the dis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Orthopaedic Surgery and Research

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2009