First Metatarsophalangeal Implants

نویسندگان

  • LAWRENCE M. OLOFF
  • MICHAEL A. FEIST
چکیده

Surgical correction of hallux limitus or degenerative articular disease of the first metatarsophalangeal joint (MPJ), whether as singular conditions or in the face of concomitant hallux abducto valgus, is a dilemma with which foot surgeons have struggled with for almost a century. The ideal procedure would provide adequate pain-free motion of the first MPJ without shortening the hallux or unweighting the first metatarsal in gait, and would withstand the rigors of weight, activity, and time. The advent of the implant arthroplasty procedure utilizing silicone-based joint implants was the hopeful solution to this complex problem. After years of clinical experience, however, it has unfortunately become apparent that the silicone implant is not the panacea that many had hoped it would be. Although patient satisfaction has generally been good, complications such as material and structural failure, foreign body reaction, and short implant life span have forced many surgeons to reconsider its use. However, for a very select patient population implant arthroplasty may still be an acceptable alternative. Before the development of the silicone implants, the only surgical alternatives available for the "unsalvageable" joint were arthroplasty and arthrodesis. Both these joint destructive procedures had their own individual inherent complications and problems. The development of the silicone implants was an effort to avoid these complications and to try to provide the patient with a functional and cosmetic alternative. The implant arthroplasty is by definition a joint destructive procedure. However, when utilizing the total joint implant, the patient is provided with a spacer to retain hallux length and functional motion for the first MPJ. This chapter specifically addresses the implant arthroplasty as it is applied to the first MPJ. The bulk of the discussion relates to the total joint implant, although the hemi-implant is also discussed. Implant materials and designs are explained, as are the specifics of the most commonly used implants. Indications, criteria, objectives, and technical aspects of the procedure and postoperative care are also discussed, along with complications inherent to the implant arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible hinge silicone implant with or without titanium grommets for arthroplasty of the first metatarsophalangeal joint.

PURPOSE To review outcomes of 37 patients who underwent arthroplasty of the first metatarsophalangeal joint using flexible hinge silicone implants with or without titanium grommets. METHODS 36 women and one man (63 feet) underwent arthroplasty of the first metatarsophalangeal joint for rheumatoid arthritis (RA) using Swanson flexible hinge silicone toe implants with or without titanium gromme...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

First metatarsophalangeal joint replacement with modular three-component press-fit implant. Preliminary report.

PURPOSE OF THE STUDY The aim of this retrospective study was to assess functional and radiographic results of the first metatarsophalangeal joint replacement with use of unconstrained, modular, three components, porous titanium and hydroxyapatite coated, press-fit METIS® prosthesis. According to author's knowledge, results of that type of prosthesis have never been published before. MATERIAL ...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Effect of foot posture and inverted foot orthoses on hallux dorsiflexion.

A pronated foot posture is considered to be a factor in limitation of dorsiflexion at the first metatarsophalangeal joint during weightbearing. Customized foot orthoses are widely used to increase dorsiflexion at the first metatarsophalangeal joint in people with pronated feet. However, the effect of foot posture and customized foot orthoses on maximum first metatarsophalangeal joint dorsiflexi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002