Successful laryngeal mask airway Fastrach intubation in the presence of an endotracheal tube inserted via the cricothyroid route.
نویسندگان
چکیده
CAN J ANESTH 55: 6 www.cja-jca.org June, 2008 References 1 Melarkode K, Prinzhausen H. Hemoglobin M variant and congenital methemoglobinemia: methylene blue will not be effective in the presence of hemoglobin M. Can J Anesth 2008; 55: 129–30. 2 Schweitzer SA. Spurious pulse oximeter desaturation due to methaemoglobinaemia. Anaesth Intensive Care 1991: 19: 269–71. 3 Cassady G. Transcutaneous monitoring in the newborn infant. J of Paediatrics 1983; 103: 837–48. 4 Southall DP, Bignall S, Stebbens VA, Alexander JR, Rivers RP, Lissauer T. Pulse oximeter and transcutaneous arterial oxygen measurements in neonatal and paediatric intensive care. Arch Dis Child 1987; 62: 882–8. 5 Huch A, Huch R, Arner B, Booth G. Continuous transcutaneous oxygen tension measured with a heated electrode. Scand J Clin Lab Invest 1973; 31: 269–75. 6 Eberhard P, Mindt W. Interference of anaesthetic gases at oxygen sensors. Birth Defects Orig Artic Ser 1979; 15: 65–74.
منابع مشابه
The intubating laryngeal mask airway in failed fibreoptic intubation.
PURPOSE Prediction of difficult tracheal intubation is not always reliable and management with fibreoptic intubation is not always successful. We describe two cases in which blind intubation through the intubating laryngeal mask airway (ILMA FasTrach) succeeded after fibreoptic intubation failed. CLINICAL FEATURES The first patient, a 50 yr old man, was scheduled for elective craniotomy for i...
متن کاملA Study to Evaluate Intubation Through Intubating Laryngeal Mask Airway Using Conventional Polyvinyl Chloride Endotracheal Tube
Background: A purposely designed wire reinforced silicone tube is available for tracheal intubation through intubating laryngeal mask airway (ILMA). However, this tube is expensive and not always available. Hence, cheaper and readily available alternatives such as conventional polyvinyl chloride (PVC) endotracheal tube should be evaluated for intubation through ILMA. Methods: After informed con...
متن کاملPREHOSPITAL CARE Securing the prehospital airway: a comparison of laryngeal mask insertion and endotracheal intubation by UK paramedics
Objectives: The recent introduction of a disposable laryngeal mask airway has provided paramedics with an alternative to endotracheal intubation. Time taken to secure the airway with each device was compared in patients undergoing elective surgery. Methods: Patients undergoing general anaesthesia were studied. Paramedics trained in laryngeal mask use and endotracheal intubation participated in ...
متن کاملSecuring the prehospital airway: a comparison of laryngeal mask insertion and endotracheal intubation by UK paramedics.
OBJECTIVES The recent introduction of a disposable laryngeal mask airway has provided paramedics with an alternative to endotracheal intubation. Time taken to secure the airway with each device was compared in patients undergoing elective surgery. METHODS Patients undergoing general anaesthesia were studied. Paramedics trained in laryngeal mask use and endotracheal intubation participated in ...
متن کاملA Prospective Randomized Comparative Study on i-gel versus Laryngeal Mask Airway Fastrach as a Conduit for Blind Tracheal Intubation Using Conventional PVC Endotracheal Tubes in Reverse Orientation
Introduction: Laryngeal mask airway (LMA) Fastrach was specially designed as a conduit for blind tracheal intubation in anticipated difficult airway and where we do not require neck extension. i-gel is a disposable, cheap supraglottic device with wide bore stem which facilitates direct passage of a conventional polyvinylchloride (PVC) endotracheal tube. Materials and Methods: A total of 80 adul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 55 6 شماره
صفحات -
تاریخ انتشار 2008