Experimental exposure to propylene glycol mist in aviation emergency training: acute ocular and respiratory effects.

نویسندگان

  • G Wieslander
  • D Norbäck
  • T Lindgren
چکیده

OBJECTIVES Propylene glycol (PG) (1-2 propanediol; CAS No 57-55-6) is a low toxicity compound widely used as a food additive, in pharmaceutical preparations, in cosmetics, and in the workplace-for example, water based paints, de-icing fluids, and cooling liquids. Exposure to PG mist may occur from smoke generators in discotheques, theatres, and aviation emergency training. Propylene glycol may cause contact allergy, but there is sparse information on health effects from occupational exposure to PG. METHODS Non-asthmatic volunteers (n=27) were exposed in an aircraft simulator to PG mist over 1 minute, during realistic training conditions. Geometric mean concentration of PG was 309 mg/m3 (range 176-851 mg/m3), with the highest concentrations in the afternoon. The medical investigation was performed both before and after the exposure (within 15 minutes). It included an estimate of tear film stability break up time, nasal patency by acoustic rhinometry, dynamic spirometry, and a doctor's administered questionnaire on symptoms. RESULTS After exposure to PG mist for 1 minute tear film stability decreased, ocular and throat symptoms increased, forced expiratory volume in 1 second/forced vital capacity (FEV1/FVC) was slightly reduced, and self rated severity of dyspnoea was slightly increased. No effect was found for nasal patency, vital capacity (VC), FVC, nasal symptoms, dermal symptoms, smell of solvent, or any systemic symptoms. Those exposed to the higher concentrations in the afternoon had a more pronounced increase of throat symptoms, and a more pronounced decrease of tear film stability. In four subjects who reported development of irritative cough during exposure to PG, FEV1 was decreased by 5%, but FEV1 was unchanged among those who did not develop a cough. Those who developed a cough also had an increased perception of mild dyspnoea. CONCLUSION Short exposure to PG mist from artificial smoke generators may cause acute ocular and upper airway irritation in non-asthmatic subjects. A few may also react with cough and slight airway obstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بهینه‌سازی فرآیند حذف پروپیلن در یک راکتور لجن فعال متعارف به کمک روش تحلیل آزمایشات تاگوچی

Background and Objective: Exposure to propylene glycol can lead to many health risks on blood, skin and kidney. Biodegradation of synthetic wastewater containing propylene glycol was studied in a continuous conventional activated sludge bench scale reactor. Optimum conditions of microorganisms' growth for biodegradation of propylene glycol were determined by Taguchi method. Materials and Method...

متن کامل

P-27: Assessment of the Contraceptive Effects of Cyclo Hexyl and Propylene Glycol on Histological Changes of Rat Seminiferous Tubules

Background: According to highlighted role of men in family planning, the use of reversible methods of contraception with no adverse effects on androgen-dependent metabolic reactions is very important. Therefore, in order to achieve a conductor combination in the designing contraceptive drugs, in the study, the effect of two drugs: Propylene glycol and Cyclo Hexyl on histological parameters of s...

متن کامل

Experimental Investigation on the Thermal Conductivity and Viscosity of ZnO Nanofluid and Development of New Correlations

In this paper, the measurement of the viscosity of ZnO in ethylene glycol, propylene glycol, mixture of ethylene glycol and water (60:40 by weight), and a mixture of propylene glycol and water (60:40 by weight) and the thermal conductivity in ethylene glycol and propylene glycol as base fluids in the range of temperature from 25 ºC to 60 ºC are investigated. The results indicate that as the tem...

متن کامل

Acute effects of nicotine-free and flavour-free electronic cigarette use on lung functions in healthy and asthmatic individuals

We designed a crossover and placebo-controlled trial to investigate the impact of a 1-h acute vaping session of nicotine-free and flavour-free e-liquid on the pulmonary functions and respiratory mechanics of healthy and asthmatic individuals. This study shows that a 1-h vaping session of a high-grade and contaminant-free mixture of propylene glycol and glycerol using a commercially available el...

متن کامل

بررسی مقایسه ای عوامل مؤثر بر تعیین تراکم کروم شش ظرفیتی بعنوان یک سرطانزای شغلی

Introduction & Objective: Hexavalent chromium, Cr+6, is a very harmful pollutant and a relatively unstable compound that is present in many industries. It is a known human respiratory carcinogen and occupational exposure to this chemical is associated with different health hazards. The purpose of this study was to evaluate the effects of four parameters including: type of sampling head, sampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 58 10  شماره 

صفحات  -

تاریخ انتشار 2001