Active handheld instrument for error compensation in microsurgery
نویسندگان
چکیده
Physiological hand tremor and other manual positioning errors limit precision in microsurgical procedures. Our research has involved development of adaptive algorithms and neural network methods for real-time compensation of such errors. This paper presents a novel design for an active hand-held microsurgical instrument to implement these algorithms, particularly during vitreoretinal microsurgery. The basic vitreoretinal instrument consists of a handle fitted with a narrow intraocular shaft to provide access to the interior of the eye. In our design, the instrument handle incorporates six-degree-offreedom inertial sensing to determine the three-dimensional position of the instrument tip. The intraocular shaft is attached to the instrument handle via a miniature parallel manipulator with three degrees of freedom, controlled by three piezoelectric elements. The manipulator actuates the intraocular shaft in pitch, yaw, and axial extension, allowing the system to perform active compensation of errors in the position of the tip of the intraocular shaft. The paper includes the formulation of the inverse kinematics of the instrument in a manner suitable for online computation. A discussion of practical design considerations and the methods and results of preliminary experiments are also presented.
منابع مشابه
Toward active tremor canceling in handheld microsurgical instruments
This paper describes research in active instruments for enhanced accuracy in microsurgery. The aim is to make accuracy enhancement as transparent to the surgeon as possible. Rather than using a robotic arm, we have taken the novel approach of developing a handheld instrument that senses its own movement, distinguishes between desired and undesired motion, and deflects its tip to perform active ...
متن کاملActive Tremor Compensation in Handheld Instrument for Microsurgery
......................................................................................................................... iii Acknowledgement .......................................................................................................... v Table of Content ........................................................................................................... vii List of Figures ....
متن کاملAugmenting the human-machine interface: improving manual accuracy
We present a novel application of a neural network to augment manual precision by canceling involuntary motion. This method may be applied in microsurgery, using either a telerobotic approach or active compensation in a handheld instrument. A feedforward neural network is trained to input the measured trajectory of a handheld tool tip and output the intended trajectory. Use of the neural networ...
متن کاملModeling and Control of Piezoelectric Actuators for Active Physiological Tremor Compensation
Humans have intrinsic limitations in manual positioning accuracy due to small involuntary movements that are inherent in normal hand motion. Among the several types of erroneous hand movements, physiological tremor is well studied and documented. Physiological tremor is roughly sinusoidal, in the frequency band of 8 – 12 Hz, and measures about 50 μm rms or more in each principal direction. Phys...
متن کاملAn Active Hand-held Instrument for Enhanced
This paper presents the first prototype of an active hand-held instrument to sense and compensate physiological tremor and other unwanted movement during vitreoretinal microsurgery. The instrument incorporates six inertial sensors (three accelerometers and three rate gyros) to detect motion of the handle. The movement of the instrument tip in three dimensions is then obtained using appropriate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1997