Internal validation of an automated system for brachial and femoral flow mediated dilation

نویسندگان

  • Brycen Ratcliffe
  • Robert Pawlak
  • Francisco Morales
  • Caleb Harrison
  • Alvaro N. Gurovich
چکیده

BACKGROUND Flow Mediated Dilation (FMD) has immense potential to become a clinical, non-invasive biomarker of endothelial function and nitric oxide bioavailability, which regulate vasomotor activity. Unfortunately, FMD analysis techniques could deviate significantly in different laboratories if a validation process is not involved. The purpose of this study was to provide validation to the assessment of FMD analysis in our laboratory and to standardize this process before reporting results of FMD. METHODS Brachial and femoral arteries FMD were performed on 28 apparently healthy participants (15 male and 13 female, ages 18-35 years). For the intratester reliability study, nine subjects were asked to come to the lab for a second brachial FMD within 48 h. All FMD procedures were performed by the same investigator, while the FMD analyses were performed by 2 independent testers who were blind to each other's analyses. FMD analyses included baseline artery diameter measurements, peak artery diameter after 5 min of ischemia, and FMD. Analysis was completed via an automated edge detection system by both testers after training of the methodical process of analysis to minimize variability. Intratester and intertester reliability were determined by using coefficient of variation (CV) between first and second visit (intratester) and between results obtained by both testers (intertester). RESULTS The intratester CVs for tester 1 and 2 were 3.28 and 2.62%, 3.74 and 3.27%, and 4.95 and 2.38% for brachial baseline artery diameter, brachial peak artery dilation, and brachial FMD, respectively. In the intertester CVs were 2.40, 3.16, and 3.37% for brachial baseline artery diameter, peak artery dilation, and FMD, respectively and 4.52, 5.50, and 3.46% for femoral baseline artery diameter, peak artery dilation, and FMD, respectively. CONCLUSION All CVs were under or around 5%, confirming a strong reliability of the method. Our laboratory has shown that the FMD protocol is reproducible due to the significantly low coefficient of variation. This is one step closer to use FMD as a biomarker for endothelial function in our laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Why is flow-mediated dilation dependent on arterial size? Assessment of the shear stimulus using phase-contrast magnetic resonance imaging.

Flow-mediated dilation (FMD) is strongly dependent on arterial size, but the reasons for this phenomenon are poorly understood. We have previously shown that FMD is greater in small brachial arteries because the shear stress stimulus is greater in small brachial arteries. However, it is unclear why the shear stimulus is greater in small arteries. Furthermore, this relationship has not been inve...

متن کامل

Non-invasive measurements of arterial structure and function: repeatability, interrelationships and trial sample size.

1. Repeatability of measurements of arterial compliance and flow-mediated dilation of the brachial artery has been infrequently reported, despite increasing use in interventional and risk-factor modification studies. Furthermore, little is known about the interrelationships of the various indices. The purposes of this study were to determine the repeatability and interrelationships of a range o...

متن کامل

Isometric handgrip training does not improve flow-mediated dilation in subjects with normal blood pressure.

Isometric HG (handgrip) training lowers resting arterial BP (blood pressure), yet the mechanisms are elusive. In the present study, we investigated improved systemic endothelial function as a mechanism of arterial BP modification following isometric HG training in normotensive individuals. This study employed a within-subject repeated measures design primarily to assess improvements in BA FMD (...

متن کامل

Identification of Atherosclerotic Changes Using B-Mode Ultrasonography in Nigerian Children with Type 1 Diabetes Mellitus

Background: This study aimed at documenting the degree of atherosclerosis, which is an important macrovascular complication in Nigerian children with Type 1 Diabetes Mellitus as determined by ultrasonography using the carotid, femoral and brachial arteries. Method: A prospective observational study was performed on all 10 children diagnosed with diabetes mellitus at the paediatric endocrinology...

متن کامل

Vascular function in children with repaired tetralogy of Fallot.

We compared the endothelial function and vascular wall characteristics of 11 children with tetralogy of Fallot (TOF) (age 13 +/- 3 years) with the characteristics of 17 age-matched peers (12 +/- 2 years). Echocardiographic Doppler measurements were performed under standardized conditions to assess (1) the carotid and femoral artery diameter and intima-media thickness, (2) brachial artery endoth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2017