Analysis on protection coordination of protective devices with a fault current limiter in the application location of a dispersed generation
نویسندگان
چکیده
As one of the solution of the increase problem of the fault current in a power system, the superconducting fault current limiter (SFCL) has been noticed as the attractive device because it has no power loss in a normal time and can limit the fault current rapidly without additional device to detect the fault current. However, the introduction of the SFCL in a power distribution system affects the protection coordination between the existing protective devices such as the over-current relay (OCR) and the recloser, which causes the operation of the protective devices to get out of their original setting values. Therefore, the analysis on the effect of the SFCL introduction on the existing protective devices is required and the method to keep the protection coordination between the protective devices in a power system with the SFCL should be first considered. In this paper, the protection with a SFCL due to application location of a DG in power distribution system was analyzed. The lower resistance generation of the SFCL due to the decrease of the feeder current in case that the DG was applied into the middle point of the fault feeder was analyzed.
منابع مشابه
مکانیابی خطا در خطوط انتقال با حضور محدودکننده جریان خطا
Fault location is an interesting subject in power grids. On the other hand, the application of fault current limiter (FCL) has been increasing in power network and causes some problems in operation of protection systems. This paper studies the application of FCL in power system and its effect on one-ended simple reactance fault location methods. In these methods, only voltages and currents of t...
متن کاملInfluence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملDecreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points
Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...
متن کاملStudy of Superconducting Fault Current Limiter Device in a AC Railway System
Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...
متن کاملSystem Stability-Constrainted Optimal Protection Coordination in the Microgrid Including Renewable Energy Sources and Energy Storage
In this paper, the system stability-constrianted optimal protection coordination (SSCOPC) as stochastic problem in the microgrid with grid-connected and islanded operation modes, including renewable energy sources (RESs) and energy storage systems (ESSs), is presented. This problem to optimal regulation of the dual setting overcurrent relays (DSORs) and selecting the reactance size of fault cur...
متن کامل