A comparison of endotracheal tube cuff pressures using estimation techniques and direct intracuff measurement.
نویسندگان
چکیده
Cuffed endotracheal tubes are one aspect of airway management designed to ensure safety, yet patients can be at risk for injury from underinflated and overinflated endotracheal cuffs. Tracheal pressures exceeding approximately 48 cm H2O impede capillary blood flow, potentially causing tracheal damage, and pressures below approximately 18 mm Hg may increase the risk of aspiration. There is no standard identified in the literature describing the method of cuff inflation, and nurse anesthetists use various cuff inflation techniques. The purpose of this study was to compare endotracheal cuff pressures obtained by estimation techniques with direct endotracheal cuff pressure measurements. A convenience sample of 40 anesthesia providers (nurse anesthesia students, Certified Registered Nurse Anesthetists, and anesthesiologists) inflated the endotracheal tube cuff using their usual inflation technique. The endotracheal tube cuff pressure was measured with a noninvasive manometer connected to the pilot balloon. Pressures obtained by estimation techniques ranged from 6 to 60 cm H2O (mean = 44.5; SD = 13.07). Analysis revealed that fewer than one third of the anesthesia providers inflated the cuff within an ideal range. No differences were found between level of anesthesia provider and cuff inflation pressures. We conclude that estimation techniques for cuff inflation are inadequate and suggest that direct measurements be used.
منابع مشابه
Intracuff pressures in endotracheal and tracheostomy tubes. Related cuff physical characteristics.
This study compared intracuff pressure (ICP) during mechanical ventilation in a variety of currently used endotracheal (ET) and tracheostomy (trach) tube cuffs and related cuff physical characteristics. Tracheostomy tube physical characteristics were also measured. Variation was observed to exist between "just-seal" inspiratory and end-expiratory intracuff pressure during mechanical ventilation...
متن کاملComparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level
Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...
متن کاملLeakage of fluid around endotracheal tube cuffs: a cadaver study
BACKGROUND The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. METHODS Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülk...
متن کاملDirect measurement of mucosal pressures exerted by cuff and non-cuff portions of tracheal tubes with different cuff volumes and head and neck positions.
We measured directly mucosal pressures against the cuff and non-cuff portions of the tracheal tube in different head-neck positions and tested the reliability of calculated mucosal pressures, in vivo intracuff pressures and cuff volume as determinants of directly measured mucosal pressures. We studied 10 anaesthetized, paralysed adult patients. An 8.5-mm, high volume, low pressure PVC tracheal ...
متن کاملEndotracheal tube cuff pressure: need for precise measurement.
CONTEXT High compliance endotracheal tubes cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage. OBJECTIVE We tested the hypothesis that endotracheal tube cuff pressures are routinely high (above 40 cmH2O) in the Post Anesthesia Care Unit (PACU) or Intensive Care Uni...