Effectiveness of duct cleaning methods on newly installed duct surfaces.

نویسندگان

  • R Holopainen
  • V Asikainen
  • M Tuomainen
  • M Björkroth
  • P Pasanen
  • O Seppänen
چکیده

Two kinds of air duct cleaning methods, mechanical brushing with different brushes and compressed air cleaning, were compared in the laboratory and in newly built buildings. The ducts were contaminated either with test dust or with dust originated from a construction site. The amount of dust on the duct surface was measured with the vacuum test method and estimated visually before and after the cleaning. In addition, the cleaning times of the different techniques were compared and the amount of residual oil in the ducts was measured in the laboratory test. The brushing methods were more efficient in metal ducts, and compressed air cleaning was more efficient in plastic ducts. After the duct cleaning the mean amount of residual dust on the surface of the ducts was <or=0.1 g/m2 in the laboratory test with ducts contaminated at construction site and <or=0.3 g/m2 after cleaning in the field. The decrease in the dust deposits on the surface ranged from 86 to 99% and from 75 to 94% in the ducts cleaned in the laboratory or in the building site, respectively. The oil residues and the dust stuck onto the oil were difficult to scrape off and remove, and none of the cleaning methods were capable of cleaning the oily duct surfaces efficiently enough. Thus new installations should consist only of oil-free ducts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dust in Ventilation Ducts: Accumulation, Measurement and Removal Report A9

This thesis focuses on dust accumulation in, and removal from, recently installed supply air ducts and on the bristle behaviour of rotating duct cleaning brushes. The results of dust accumulation, measured using three different methods, were compared and the amount of dust in newly installed air ducts was evaluated. The vacuum test was found to be an efficient method of collecting dust samples ...

متن کامل

The Stable Trajectory Tracking Control of a Skid-steered Mobile Platform with Dynamic Uncertainties

In order to clean the surfaces of air ducts in underground facilities, recent research has been conducted on driving the control and development of an autonomous mobile ductcleaning platform. The duct-cleaning robots removes contaminants that are inside a duct using the friction between a rotating cleaning brush and the duct surface. For the effective removal of the contaminants and stable stee...

متن کامل

Finite Element Method Application in Analyzing Magnetic Fields of High Current Bus Duct

The goal of paper is to present the magnetic field calculations in high current bus ducts. Finiteelement method is used to do this. Bus ducts under study have figure such as circle area. Thecalculations will be using mathematical relations, meshed geometric shape and analyzing them.Geometric mean will help us to determine the value of magnetic field. COMSOL software is appliedfor simulation stu...

متن کامل

Performance Analysis of a Mobile Duct Cleaning Robot

Inside air ventilation ducts of the confined space such as subway stations become contaminated by various contaminants and particular matters after long time operation. The accumulated various pollutants at inner duct surface easily transport and cause secondary air contamination and injure subway passengers’ respiratory system and health. In fact, only periodic duct cleaning works can improve ...

متن کامل

Assessment of conventional Crigler massage in recovery of congenital nasolacrimal duct obstruction

Introduction: We aimed to determine the success rate of conventional massage in congenital nasolacrimal duct obstruction. Methods: 45 children attending to eye clinic with congenital nasolacriml duct obstruction initially were treated with Crigler massage as conventional procedure. We therefore evaluated the effect of the implemented massage upon one week. Results: The overall success rate in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 2003