Radiation dosimetry assessment of routine CT scanning protocols used in Western Australia.

نویسندگان

  • Rachael E Moorin
  • Rene Forsyth
  • David J Gibson
  • Richard Fox
چکیده

Technical data on local CT practice in Western Australia were collected for five major CT providers using a self-completed questionnaire. The CTDIvol DLP and effective dose for each protocol were obtained and providers were ranked according to radiation burden for each clinical scenario. The mean, median, 75th percentile and standard deviation were calculated for both effective dose and DLP for each scenario and these values were compared with published data. CT utilisation data were used to estimate the attributable radiation dose to the WA population and the potential change in population annual effective dose according to the protocol used was estimated. We found that wide variations in technique and radiation dose exist across providers for similar examinations, producing a higher radiation burden than reported internationally. As expected, the CT protocol used dramatically affects the radiation dose received, and this has a significant effect on annual population dose. This study highlights the need for recognition and understanding of both the degree of variation in radiation dose across providers and the relatively high radiation burden afforded by protocols in use in Western Australia so that necessary dialogue can be launched for practitioner consensus on appropriate diagnostic reference levels in CT scanning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Translation of Methdology used in Human Myocardial Imaging to a Sheep Model of Acute Myocardial Infarction

Background: Pre-clinical investigation of stem cells for repairing damaged myocardium predominantly used rodents, however large animals have cardiac circulation closely resembling the human heart. The aim of this study was to evaluate whether SPECT/CT myocardial perfusion imaging (MPI) could be used for assessing sheep myocardium following an acute myocardial infarction (MI) and response to int...

متن کامل

Reducing radiation doses in female breast and lung during CT examinations of thorax: A new technique in two scanners

Background: Chest CT is a commonly used examination for the diagnosis of lung diseases, but a breast within the scanned field is nearly never the organ of interest.Objective: The purpose of this study is to compare the female breast and lung doses using split and standard protocols in chest CT scanning.Materials and Methods: The sliced chest and breast female phantoms were used. CT exams were p...

متن کامل

The Impact of Iterative Reconstruction on Computed Tomography Radiation Dosimetry: Evaluation in a Routine Clinical Setting

PURPOSE To evaluate the effect of introduction of iterative reconstruction as a mandated software upgrade on radiation dosimetry in routine clinical practice over a range of computed tomography examinations. METHODS Random samples of scanning data were extracted from a centralised Picture Archiving Communication System pertaining to 10 commonly performed computed tomography examination types ...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Development of Computed Tomography Head and Body Phantom for Organ Dosimetry

Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiological protection : official journal of the Society for Radiological Protection

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 2013