Angiographic CT after intravenous contrast agent application: A noninvasive follow-up tool after intracranial angioplasty and stenting.

نویسندگان

  • M-N Psychogios
  • P Schramm
  • J-H Buhk
  • A Xyda
  • K Gröschel
  • K Jung
  • M Knauth
چکیده

BACKGROUND AND PURPOSE ICAS is one of the therapeutic options in symptomatic cerebral artery stenosis. iaDSA is the current criterion standard examination after ICAS for the detection of ISR. In this study, we evaluated ivACT as a potential noninvasive follow-up alternative. MATERIALS AND METHODS In 17 cases, ivACT and iaDSA were performed after ICAS. Both procedures were carried out on a flat-panel-detector-equipped angiography system. Postprocessing of ivACT acquisitions was performed on a dedicated workstation producing multiplanar reformations of the stent region and other intracranial arteries. Restenotic lesions were compared with iaDSA measurements. All studies were independently evaluated by 2 experienced neuroradiologists blinded to patients data. RESULTS In 5 cases, ISR was diagnosed on iaDSA images. All restenotic lesions were reliably detected (sensitivity, 100%; 95%CI, 48%-100%) and could be correctly quantified on ivACT images in comparison with iaDSA. The neuroradiologists correctly excluded ISR in 11 of 12 lesions after viewing the ivACT examinations (specificity, 92%; 95%CI, 62%-100%). Measurements of ISR on ivACT were highly correlated to iaDSA (Pearson r = 0.94, P < .01). CONCLUSIONS IvACT is a promising noninvasive follow-up examination after ICAS. With its high spatial resolution, it can reliably detect or exclude ISR. Contrary to iaDSA, there is no need for a recovery period after ivACT and the risk of neurologic complications is practically lowered to zero.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of intracranial in-stent restenosis using quantitative magnetic resonance angiography.

BACKGROUND AND PURPOSE In-stent restenosis (ISR) after angioplasty/stenting for intracranial stenosis has been reported in up to 25% to 30% of patients. Detection and monitoring of ISR relies primarily on serial catheter angiography, because noninvasive imaging methods are typically hampered by stent-related artifact. We examined the value of serial vessel flow measurements using quantitative m...

متن کامل

Optimized angiographic CT using intravenous contrast injection: a noninvasive imaging option for the follow-up of coiled aneurysms?

BACKGROUND AND PURPOSE Because recanalization of coiled cerebral aneurysms is reported to occur, follow-up imaging is mandatory, ideally noninvasively. Our study aimed to evaluate the accuracy of an optimized angiographic CT by using intravenous contrast material injection in the assessment of coiled cerebral aneurysms, compared with MR angiography and digital subtraction angiography, the crite...

متن کامل

Optimal coronary balloon angioplasty with provisional stenting versus primary stent (OCBAS): immediate and long-term follow-up results.

OBJECTIVE This study sought to compare two strategies of revascularization in patients obtaining a good immediate angiographic result after percutaneous transluminal coronary angioplasty (PTCA): elective stenting versus optimal PTCA. A good immediate angiographic result with provisional stenting was considered to occur only if early loss in minimal luminal diameter (MLD) was documented at 30 mi...

متن کامل

Hemodynamic changes in the basilar artery following stenting.

A 75-year-old man had a 2-week history of recurrent, in crescendo episodes of diplopia, dizziness, dysarthria, and right-sided hemiparesis. Transcranial color-coded sonography (TCCS) showed a severe proximal basilar artery (BA) stenosis with an enddiastolic flow velocity of 142 cm/sec (figure, A, arrow) confirmed by angiography. BA angioplasty and stent application was performed in view of pers...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 31 10  شماره 

صفحات  -

تاریخ انتشار 2010