Radial sample preconcentration.
نویسندگان
چکیده
In this paper we present a radial sample preconcentration strategy enabled by axisymmetric concentration polarization in a microfluidic chamber on a uniform nanoporous film. Sample analytes are focused into the centre, creating a concentrated plug that is injected vertically into the microfluidic analysis layer. No balancing pressure driven flows or tangential fields are required, and the process has essentially zero footprint on the analysis layer. An electrokinetic loading scheme enables repeat loading/concentration cycles, and a finned radial chamber geometry dampens instabilities and accommodates larger volumes. Modelling results indicate over 1800-fold concentration increases are possible in 10 s, for high mobility buffers and high applied field strength. At moderate field strength and buffer mobility, experiments demonstrate a 168-fold increase in concentration of FITC-BSA protein in 36 s.
منابع مشابه
Sampling and Preconcentration for Trace Explosives Detection
A trace explosives detection system typically contains three subsystems: sample collection, preconcentration, and detection. Sample collection of trace explosives (vapor and particulate) through large volumes of airflow helps reduce sampling time while increasing the amount of dilute sample collected. Preconcentration of the collected sample before introduction into the detector improves the se...
متن کاملDevelopment of a Microfluidic Device for Performing Sample Preconcentration and Capillary Electrophoresis Separation
We report on a microfabricated device for sample preconcentration and capillary electrophoresis (CE) separation in a glass microchip. The device allows highly efficient anion-selective preconcentration to be performed with a micro-nanomicrochannel structure. An integrated cross channel enables gate-injection of the preconcentrated sample into the analysis channel for CE separation. Sample preco...
متن کاملPreconcentration in Inorganic Trace Analysis
Preconcentration in trace analysis lowers the detection limit, simplifies the treatment of a representatIve sample, facilitates calibration, reduces the need for various standard reference samples and frequently involves separation of the matrix in analysis of toxic, radioactive and expensive materials. In this paper, the types of preconcentration are considered and quantitative characteristics...
متن کاملAutomated On-line Preconcentration System for Electrothermal Atomic Absorption Spectrometry for the Determination of Copper and Molybdenum in Sea-water
absorption spectrometry was developed. The performance of retain transition metal ions. After the sample loading step, the the on-line preconcentration system was tested by determining metal ions are stripped from the column with a suitable eluent Cu and Mo in sea-water. Calibration graphs constructed from and directly injected into the nebulizer of a flame atomic the preconcentration of standa...
متن کاملOn-line preconcentration in capillary electrochromatography using a porous monolith together with solvent gradient and sample stacking.
Preconcentration effects of solvent gradient and sample stacking are investigated on a photopolymerized sol-gel (PSG) in capillary electrochromatography. The porous PSG monolith has a high mass-transfer rate. This characteristic promotes preconcentration of dilute samples. Plugs of samples more than 2 cm in length prepared in the separation solution (nongradient condition) are injected onto the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 11 6 شماره
صفحات -
تاریخ انتشار 2011