Precise slit-width control of niobium apertures for superconducting LEDs.
نویسندگان
چکیده
We introduce a novel three-step procedure for precise niobium (Nb)-etching on the nanometer-scale, including the design of high contrast resist patterning and sacrifice layer formation under high radio frequency (RF) power. We present the results of precise slit fabrication using this technique and discuss its application for the production of superconducting devices, such as superconductor-semiconductor-superconductor (S-Sm-S) Josephson junctions. For the reactive ion etching (RIE) of Nb, we selected CF(4) as etchant gas and a positive tone resist to form the etching mask. We found that the combination of resist usage and RIE process allows for etching of thicker Nb layers when utilizing the opposite dependence of the etching rate (ER) on the CF(4) pressure in the case of Nb as compared to the resist. Precise slit-width control of 80 and 200 nm thick Nb apertures was performed with three kinds of ER control, for the resist, the Nb, and the underlying layer. S-Sm-S Josephson junctions were fabricated with lengths as small as 80 nm, which can be considered clean and short and thus exhibit critical currents as high as 50 µA. Moreover, possible further applications, such as for apertures of superconducting light emitting diodes (SC LEDs), are addressed.
منابع مشابه
Magnetoresistance anisotropy of a one-dimensional superconducting niobium strip.
We investigated confinement effects on the resistive anisotropy of a superconducting niobium strip with a rectangular cross section. When its transverse dimensions are comparable to the superconducting coherence length, the angle dependent magnetoresistances at a fixed temperature can be scaled as R(theta,H) = R(H/Hctheta) where Hctheta =Hc0(cos2theta + gamma(-2)sin2theta)(-1/2) is the angular ...
متن کاملDiffraction and Interference
We measure the patterns produced by a CW laser near 650 nm passing through one and two slit apertures with a detector mounted on a linear translator. Data collected for a single slit of width a = .04 mm is used to measure the wavelength of light. Data collected for a double slit aperture of slit separation d ~ .25 mm and width a ~ .04 mm is fit with an algorithm that varies the parameters a and...
متن کاملCritical field for complete vortex expulsion from narrow superconducting strips.
We have measured the maximum field for which vortices are completely expelled from a thin-film superconducting strip. Niobium strips of width W were field cooled and imaged with a scanning Hall-probe microscope. Below a critical field B(m) approximately Phi(0)/W(2) all flux was expelled; above this field vortices were observed with a density increasing approximately linearly with field. The sma...
متن کاملSTIS Instrument Science Report 98-20 CLEAR APERTURE FRACTIONAL TRANSMISSION FOR POINT SOURCES
The fractional transmission as a function of wavelength for stellar objects is measured for clear apertures by comparing count rates through small apertures to open aperture count rates in STIS first order modes. Because OTA "breathing" causes the throughput of the smallest apertures to vary on short time scales, the best estimate of the aperture throughputs is a theoretical model that is based...
متن کاملResonant microwave transmission through individual sub-wavelength slits
It is well established that much more radiation may be transmitted through a set of apertures in a metallic screen than a simple calculation from the transmission through the aperture area alone would predict. There has been substantial debate regarding the exact cause of this enhanced transmission, and confusion over the difference between the behaviour of subwavelength apertures as opposed to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nanotechnology
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2011