Overtube-assisted enteroscopy and capsule endoscopy for the diagnosis of small-bowel polyps and tumors: a systematic review and meta-analysis.

نویسندگان

  • Marianny Sulbaran
  • Eduardo de Moura
  • Wanderley Bernardo
  • Cintia Morais
  • Joel Oliveira
  • Leonardo Bustamante-Lopez
  • Paulo Sakai
  • Klaus Mönkemüller
  • Adriana Safatle-Ribeiro
چکیده

BACKGROUND AND STUDY AIMS Several studies have evaluated the utility of double-balloon enteroscopy (DBE) and capsule endoscopy (CE) for patients with small-bowel disease showing inconsistent results. The aim of this study was to determine the sensitivity and specificity of overtube-assisted enteroscopy (OAE) as well as the diagnostic concordance between OAE and CE for small-bowel polyps and tumors. PATIENTS AND METHODS We conducted a systematic review and meta-analysis of studies in which the results of OAE were compared with the results of CE for the evaluation of small-bowel polyps and tumors. When data for surgically resected lesions were available, the histopathological results of OAE and surgical specimens were compared. The sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio for the diagnosis of small-bowel polyps and tumors were analyzed. Secondarily, the rates of diagnostic concordance and discordance between OAE and CE were calculated. RESULTS There were 15 full-length studies with a total of 821 patients that met the inclusion criteria. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were as follows: 0.89 (95 % confidence interval [CI] 0.84 - 0.93), with heterogeneity χ(2) = 41.23 (P = 0.0002) and inconsistency (I (2)) = 66.0 %; 0.97 (95 %CI 0.95 - 0.98), with heterogeneity χ(2) = 45.27 (P = 0.07) and inconsistency (I (2)) = 69.1 %; 16.61 (95 %CI 3.74 - 73.82), with heterogeneity Cochrane's Q = 225.19 (P < 0.01) and inconsistency (I (2)) = 93.8 %; and 0.14 (95 %CI 0.05 - 0.35), with heterogeneity Cochrane's Q = 81.01 (P < .01) and inconsistency (I (2)) = 82.7 %, respectively. A summary receiver operating characteristic curve (SROC) curve was constructed, and the area under the curve (AUC) was 0.97. CONCLUSION OAE is an accurate test for the detection of small-bowel polyps and tumors. OAE and CE have a high diagnostic concordance rate for small-bowel polyps and tumors. This study was registered in the PROSPERO international database (www.crd.york.ac.uk/prospero/) with the study number CRD42015016000.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis and Treatment of Small Bowel Cancers Using Radioactive Gold Nanoparticles and Wireless Fluorescence Capsule Endoscopy

Background: Therapeutic and diagnosis properties of radioactive gold nanoparticle (198-AuNPs) cause them to be suitable for detection and treatment of tumors.Objective: Electrical and optical properties of PEG-198AuNPs were examined in this paper. Polyethylene Glycol (PEG)-198 AuNPs can be used for treatment and diagnosis of small intestine tumors.Methods: Wireless fluorescence capsule endoscop...

متن کامل

European Society of Gastrointestinal Endoscopy (ESGE) Guidelines: flexible enteroscopy for diagnosis and treatment of small-bowel diseases.

Until recently, large parts of the small bowel were not accessible with nonsurgical endoscopic techniques. In this scenario, the advent of video capsule endoscopy and balloon−assisted ente− roscopy represented a major breakthrough. Although capsule endoscopy is a safe method that may provide imaging of the entire small bowel, major drawbacks are that biopsy sampling and endoscopic treatment can...

متن کامل

Enteroscopy.

Noninvasive imaging with CT and magnetic resonance enterography or direct visualization with wireless capsule endoscopy can provide valuable diagnostic information and direct therapy. Enteroscopy technology and techniques have evolved significantly and allow diagnosis and therapy deep within the small bowel, previously attainable only with intraoperative enteroscopy. Push enteroscopy, readily a...

متن کامل

Spiral enteroscopy: a new twist on overtube-assisted endoscopy.

Until recently, the small bowel remained beyond the reach of direct endoscopic inspection outside the operating room. No matter how hard the endoscopist pushed a floppy tube, the twists and contours of the gut eventually ganged up, loops formed, and forward motion ended. Novel endoscope designs, like the Sondé enteroscope that relied on gut motility to move the tip through the bowel, proved too...

متن کامل

Small Bowel Neoplasias: Current Options for Diagnosis, Staging and Therapeutic Management

Although small bowel polyps and tumors are rare, their incidence has increased significantly over the past 30 years. Small bowel malignancies can be classified depending upon their cellular origin into four principal histologic types: adenocarcinomas, lymphomas, neuroendocrine tumors or carcinoids and lymphomas, which also include gastrointestinal stromal tumors. The relative ‘rarity’ of these ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy international open

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2016