Evaluation of determination of glucose in urine with some commercially available dipsticks and tablets.
نویسندگان
چکیده
Four commercial products for urine glucose determination were evaluated and compared with a quantitative hexokinase procedure. We examined precision, sensitivity, and analytical recovery of glucose from glucose-supplemented urine samples and comparison of methods, using patients' samples. Only "Chemstrip uG" (Bio-Dynamics Inc.) could differentiate between 0.3 g/L (upper limit of normal) and 0.6 g/L urine glucose concentrations. "Tes-Tape" (Lilly) and "Diastix" (Ames) gave positive readings at 0.3 g/L; "Clinitest" (Ames) detected glucose only over 1 g/L. Analytical recovery of glucose was best, for all four products, between 1 and 2.5 g/L; Chemstrip uG was the most nearly accurate among the four. Between 5 and 20 g/L glucose concentrations, Tes-Tape, Diastix, and Clinitest tended to give falsely low results; the use of Chemstrip uG resulted in overestimates of concentration at 20 g of glucose per liter. Only Chemistrip uG and Clinitest (two-drop method) had linear ranges extending to 50 g/L; Chemstrip uG had better precision and accuracy at this concentration. Of the four products, Chemstrip uG had the lowest within-technologist and technologist-to-technologist random analytical errors. In method comparison on patients' samples, Chemstrip uG was significantly stronger in its association with the quantitative hexokinase method than was Diastix, Clinitest, or Tes-Tape.
منابع مشابه
Electroanalytical Determination of Gemifloxacin Mesylate in Bulk, Tablets and Human Urine Using Gold Nanoparticles Modified Carbon Paste Electrode
A simple, precise, inexpensive and sensitive voltammetric method has been developed for the determination of gemifloxacin mesylate (GEM) in the presence of tween 80 in the bulk, farmaceutical dosage forms and human urine at gold nanoparticles modified carbon paste electrode (GNCPE). The electrochemical behavior of GEM has been investigated by using cyclic voltammetry (CV) and differential pulse...
متن کاملUse of circulating cathodic antigen (CCA) dipsticks for detection of intestinal and urinary schistosomiasis.
An evaluation of a commercially available antigen capture dipstick that detects schistosome circulating cathodic antigen (CCA) in urine was conducted in representative endemic areas for intestinal and urinary schistosomiasis in Uganda and Zanzibar, respectively. Under field-based conditions, the sensitivity (SS) and specificity (SP) of the dipstick was 83 and 81% for detection of Schistosoma ma...
متن کاملComparison of several methods for semiquantitative determination of urinary protein.
Two types of urine protein dipsticks and the sulfosalicylic acid method were compared for their accuracy and specificity, with use of urine samples supplemented with various proteins. Dipsticks yield accurate results when the protein under consideration is restricted to albumin; the sulfosalicylic acid method accurately determines many kinds of proteins in addition to albumin. Detergents affect...
متن کاملPhotostability Determination of Commercially Available Nifedipine Oral Dosage Forms in Iran
Nifedipine (NIF) a 1, 4-dihydropyridine calcium channel antagonist, undergoes photodegradation to nitroso analogues of dehydronifedipine (NDNIF) when exposed to sunlight. Photodegradation products of NIF have no clinical activity, so different formulations of NIF must remain unchanged. If NIF preparations become unstable in exposure to light, they could cause therapeutic failure. The present st...
متن کاملPhotostability Determination of Commercially Available Nifedipine Oral Dosage Forms in Iran
Nifedipine (NIF) a 1, 4-dihydropyridine calcium channel antagonist, undergoes photodegradation to nitroso analogues of dehydronifedipine (NDNIF) when exposed to sunlight. Photodegradation products of NIF have no clinical activity, so different formulations of NIF must remain unchanged. If NIF preparations become unstable in exposure to light, they could cause therapeutic failure. The present st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 10 شماره
صفحات -
تاریخ انتشار 1982