Comparison of the numerical and clinical accuracy of four continuous glucose monitors.

نویسندگان

  • Boris Kovatchev
  • Stacey Anderson
  • Lutz Heinemann
  • William Clarke
چکیده

OBJECTIVE The purpose of this study was to compare the numerical and clinical accuracy of four continuous glucose monitors (CGMs): Guardian, DexCom, Navigator, and Glucoday. RESEARCH DESIGN AND METHODS Accuracy data for the four CGMs were collected in two studies: Study 1 enrolled 14 adults with type 1 diabetes at the University of Virginia (UVA), Charlottesville, Virginia; study 2 enrolled 20 adults with type 1 diabetes at the Profil Institute for Metabolic Research, Neuss, Germany. All participants underwent hyperinsulinemic clamps including 1.5-2 h of maintained euglycemia at 5.6 mmol/l followed by descent into hypoglycemia, sustained hypoglycemia at 2.5 mmol/l for 30 min, and recovery. Reference blood glucose sampling was performed every 5 min. The UVA study tested Guardian, DexCom, and Navigator simultaneously; the Profil study tested Glucoday. RESULTS Regarding numerical accuracy, during euglycemia, the mean absolute relative differences (MARDs) of Guardian, DexCom, Navigator, and Glucoday were 15.2, 21.2, 15.3, and 15.6%, respectively. During hypoglycemia, the MARDs were 16.1, 21.5, 10.3, and 17.5%, respectively. Regarding clinical accuracy, continuous glucose-error grid analysis (CG-EGA) revealed 98.9, 98.3, 98.6, and 95.5% zones A + B hits in euglycemia. During hypoglycemia, zones A + B hits were 84.4, 97.0, and 96.2% for Guardian, Navigator, and Glucoday, respectively. Because of frequent loss of sensitivity, there were insufficient hypoglycemic DexCom data to perform CG-EGA. CONCLUSIONS The numerical accuracy of Guardian, Navigator, and Glucoday was comparable, with an advantage to the Navigator in hypoglycemia; the numerical errors of the DexCom were approximately 30% larger. The clinical accuracy of the four sensors was similar in euglycemia and was higher for the Navigator and Glucoday in hypoglycemia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

Can the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?

Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...

متن کامل

Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy.

Continuous glucose sensors (CGS) offer the potential to greatly change the lives of people with diabetes. Even though two of these systems (Guardian RT, Medtronic, Northridge, CA, and DexCom STS, DexCom, San Diego, CA) have been approved by the Food and Drug Administration for use as adjuncts to self-blood glucose monitoring (SBGM), questions remain concerning the accuracy of these devices. Whe...

متن کامل

Evaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method

Abstract         Background and Objective: According to recent changes in diagnostic criteria for diabetes, the harmonization of results obtained from various methods and systems by considering their accuracy and precision is essential. This study aimed to evaluate the accuracy, precision and consensus of some routine laboratory glucose kits in co...

متن کامل

The comparison of continuous and intermittent training impact on glucose-4 transporter protein level and insulin sensitivity in diabetic rats

Introduction: Diabetes mellitus (DM) is now seen as a worldwide epidemic disease with high prevalence. Exercise training (ET) is known to promote beneficial changes in diabetic patients. The aim of this study was to compare the impact of continuous and intermittent aerobic training on glucose-4 transporter protein (GLUT-4) levels and insulin sensitivity in diabetic rats. Materials and meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diabetes care

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 2008