Evaluation of design parameters for a reflection based long-term pulse oximetry sensor
نویسندگان
چکیده
Pulse oximetry is a standard parameter for many years in clinical patient monitoring. There are also sensors that can be used at home. But all these sensors use the transmission based method to measure the oxygen saturation which require finger or ear clips that are uncomfortable and confining and therefore not fit for long-term monitoring. Sleep-related breathing disorders or breathing thin air in high altitudes can lead to insufficient oxygen intake. Insufficient oxygen supply can cause permanent damage to the tissue and in some cases even death. For early ambulatory diagnosis, a reflection based longterm pulse oximetry sensor would be the best solution. There are no available devices on the market, even so many studies showed promising results. That why, we evaluated design parameters for a reflection based long-term pulse oximetry sensor, located at the wrist. The prototype we developed consists of two LEDs (one red and one infrared), a photodiode and the evaluation board SLAU480B from Texas Instruments. We tested three sensor layouts and discovered that the distance between the LEDs and the photodiode, the contact pressure and motion artefacts were the most important signal influencing parameters. After the Signal processing we obtained a signal to noise ratio of 22 dB (red) and 30 dB (infrared) and a AC/DC ratio of 1-3 %, which should be more than enough to calculate the SpO2 value. Also motion artifacts were tested and seem to affect the measurement at the lower wrist strongly. In conclusion we found some reasons why there is no such device on the market yet. Keywords—Pulse oximetry; long-term monitoring; reflexion; hypoxia; sensor; SpO2; PPG
منابع مشابه
A Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
متن کاملEvaluation of Pulse Oximetry in the Early Diagnosis of Cardiac and NonCardiac Diseases in Healthy Newborns
Background: Critical congenital heart diseases (CCHDs) are among the most common birth malformations. This study aimed to determine the cardiac and noncardiac diseases in the Iranian healthy newborns using pulse oximetry (POX) as a suggested screening method.Methods: In this cross-sectional study, healthy term and near term neonates who were born from October 2017 to March 2018 were evalu...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملInitial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI
BACKGROUND Accurate synchronization between magnetic resonance imaging data acquisition and a subject's cardiac activity ("triggering") is essential for reducing image artifacts but conventional, contact-based methods for this task are limited by several factors, including preparation time, patient inconvenience, and susceptibility to signal degradation. The purpose of this work is to evaluate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- ICST Trans. Ambient Systems
دوره 3 شماره
صفحات -
تاریخ انتشار 2016