Status of the grafts and the native coronary arteries proximal and distal to coronary anastomotic sites of aortocoronary bypass grafts.
نویسندگان
چکیده
The status of the native coronary arteries at necropsy in the vicinity of the coronary anastomoses of saphenous vein aortocoronary bypass grafts in 20 patients with severe coronary heart disease is presented. Of the 37 graft systems (graft plus coronary artery into which graft inserted) analyzed, the lumina of 44% of the native coronary arteries within the first 2 cm distal to the anastomoses were greater than 75% narrowed in cross-sectional area by atherosclerotic plaques, and the native coronary artery at the site of the anastomosis was greater than 50% narrowed in cross-sectional area already by atheroclerotic plaque in 25% of the graft systems. The mean coronary arterial size distal to the site of the coronary graft anastomosis, even after correction for heart weight, was greater in the 13 men than in the seven women. The residual luminal areas squared per gram of heart weight, however, were similar in both men and women. These results suggest that 1) relative coronary vessel size is greater in men than women; 2) the luminal area squared per gram myocardial mass (a relative estimation of flow) is the same in the two groups of patients; and 3) less atherosclerotic plaque is necessary in women then in men to produce similar limitation to coronary flow. Thus, vessel size alone cannot account for the higher reported frequency of unsuccessful aortocoronary bypass procedures in women.
منابع مشابه
State of the vein grafts, native coronary arteries, and myocardium and principal cause of death in patients dying after aortocoronary bypass grafting.
Fifty five patients with 108 coronary bypass saphenous vein grafts were studied at necropsy. The mean duration of the grafts was 153 days (SD 516). The luminal narrowing of the native coronary arteries proximal to, at, and distal to the vein graft anastomoses and the narrowing of the non-grafted arteries were evaluated planimetrically. Twenty nine per cent of coronary arteries distal to graft a...
متن کاملAlteration of reactivity of native arteries induced by venous graft placement.
Occlusion of aortocoronary venous grafts can be due to thrombosis, atherosclerosis, or vasospasm. Investigations have focused on properties of the graft itself, and little is known about the vascular reactivity and function of the native arteries proximal and distal to the vein graft, although spasm of the native artery distal to the graft site has been observed in patients. We hypothesized tha...
متن کاملIncrease in severity of proximal coronary disease after successful distal aortocoronary grafts. Its nature and effects.
Aortocoronary vein grafts were placed in seven patients to bypass severe proximal stenosis in nine coronary arteries. Routine postoperative angiography showed patent grafts in all patients and substantial increase of proximal occlusive disease, diffusely or at the points of narrowing, in six of nine arteries (four patients), with complete obstruction of four of the six vessels. Two of the four ...
متن کاملExercise thallium-201 myocardial scintigraphy in the follow-up of aortocoronary bypass graft surgery.
The predictive accuracy of exercise thallium-201 (201Tl) myocardial scintigraphy in the evaluation of aortocoronary bypass graft surgery was assessed in 48 patients undergoing angiographic investigation 15 months (mean time) after myocardial revascularisation. 201Tl scintigrams detected 61 out of 77 (79%) patent grafts but only 21 out of 42 (50%) occluded grafts, though, for grafts supplying no...
متن کاملNon-invasive assessment of coronary artery bypass grafts and native coronary arteries using 64-slice computed tomography: comparison with invasive coronary angiography.
INTRODUCTION AND OBJECTIVES Although the diagnostic accuracy of CT in the non-invasive assessment of coronary arteries and grafts is known to be high, only a few studies have investigated the technique's reliability for the combined assessment of native coronary arteries, grafts, and vessels lying distal to anastomoses. The aim of this study was to evaluate the diagnostic accuracy of 64-slice C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 55 5 شماره
صفحات -
تاریخ انتشار 1977