Online detector of movement intention based on EEG - Application in tremor patients
نویسندگان
چکیده
Patients with tremor can benefit from wearable robots managing their tremor during daily living. To achieve this, the interfaces controlling such robotic systems must be able to estimate the user’s intention to move and to distinguish it from the undesired tremor. In this context, analysis of electroencephalographic activity is of special interest, since it provides information on the planning and execution of voluntary movements. This paper proposes an adaptive and asynchronous EEG-based system for online detection of the intention to move in patients with tremor. An experimental protocol with separated self-paced wrist extensions was used to test the ability of the system to detect the intervals preceding voluntary movements. Six healthy subjects and four essential tremor patients took part in the experiments. The system predicted 60 ± 10% of the movements with the control subjects and 42 ± 27% of the movements with the patients. The ratio of false detections was low in both cases (1.5 ± 0.1 and 1.4 ± 0.5 false activations per minute with the controls and patients, respectively). The prediction period with which the movements were detected was higher than in previous similar studies (1.06 ± 1.02 s for the controls and 1.01 ± 0.99 s with the patients). Additionally, an adaptive and fixed design were compared, and it was the adaptive design that had a higher number of movement detections. The system is expected to lead to further development of more natural interfaces between the assistive devices and the patients wearing them.
منابع مشابه
Online movement control in multiple sclerosis patients with tremor: effects of tendon vibration.
Patients with intention tremor due to multiple sclerosis (MS) exhibit an increased reliance on visual feedback in the sensorimotor control of slow goal-directed movements. In the present study, the use of proprioceptive information was investigated in MS patients with intention tremor compared to MS patients without tremor and healthy controls. Tendon vibration was applied to the wrist extensor...
متن کاملAdvantages of EEG phase patterns for the detection of gait intention in healthy and stroke subjects
OBJECTIVE One use of EEG-based brain-computer interfaces (BCIs) in rehabilitation is the detection of movement intention. In this paper we investigate for the first time the instantaneous phase of movement related cortical potential (MRCP) and its application to the detection of gait intention. APPROACH We demonstrate the utility of MRCP phase in two independent datasets, in which 10 healthy ...
متن کاملDesign, Implementation and Evaluation of Azmer Online Quiz Application Based on Technology Acceptance Model (TAM): A pilot study
Introduction: Acceptance and intention to use the mobile device in the student evaluation is an interesting topic in education. Although there are significant studies of mobile learning acceptance and mobile-based assessment (MBA), there is little research on app design and driving factors that influence students' intention to use mobile technology for assessment purposes. The purpose of this ...
متن کاملIntention tremor exaggerated by visually guided movement.
Intention tremor is caused by disorders of the cerebellar system. The kind of movement that exaggerates intention tremor has not yet been established. Thus, to investigate the contexts in which intention tremor is increased, I tested intention tremor patients as they performed two kinds of tasks, one involving sensory-guided movement and the other involving memory-guided movement. I report here...
متن کاملDetection of movement intention using EEG in a human-robot interaction environment
Introduction: This paper presents a detection method for upper limb movement intention as part of a brainmachine interface using EEG signals, whose final goal is to assist disabled or vulnerable people with activities of daily living. Methods: EEG signals were recorded from six naïve healthy volunteers while performing a motor task. Every volunteer remained in an acoustically isolated recording...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomed. Signal Proc. and Control
دوره 8 شماره
صفحات -
تاریخ انتشار 2013